Schneider Electric C080H35AFM — Miniature Circuit Breakers (MCB)

Schneider Electric C080H35AFM ComPacT NS 800A, 70kA 415V

MPNC080H35AFM
Active

Schneider Electric ComPacT NS new generation, C080H35AFM, 3-pole fixed MCCB, 800 A, MicroLogic 5.0 A electronic trip unit, 70 kA Icu at 415 V AC, manually operated with LCD display.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C080H35AFM — Identification
ParameterValue
Product nameComPacT NS new generation
Product rangeComPacT
Product range (series)ComPacT NS630b...1600 new generation
Product/component typeCircuit breaker
Device applicationDistribution
C080H35AFM — Ratings
ParameterValue
Rated current (In)800 A at 50 °C
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)50 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 40 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory B
Overvoltage categoryIII
C080H35AFM — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)2000 cycles at 690 V In 4000 cycles at 690 V In/2 5000 cycles at 440 V In 6000 cycles at 440 V In/2
Mechanical durability (cycles)10000 cycles
C080H35AFM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeManually operated
Local signalling/indication4 LEDs (red) for fault indication 1 LED (yellow) for overload
C080H35AFM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
Relative humidity0...95 %
C080H35AFM — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C080H35AFM — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.4...1 x In
Trip unit protection functionsLSI

Product details

What this 800 A MCCB delivers

The Schneider Electric C080H35AFM is a ComPacT NS new generation molded case circuit breaker rated 800 A at 50 °C, with a MicroLogic 5.0 A electronic trip unit providing L (long-time overload), S (short-time short-circuit), and I (instantaneous short-circuit) protection. The H breaking capacity code means 70 kA Icu at 415 V AC, 50/60 Hz, per IEC 60947-2 — enough for high-fault distribution panels where upstream coordination demands a robust interrupting rating. The 3-pole fixed-mount format with front connection (both upside and downside) suits backplate mounting in switchboards or enclosed distribution assemblies. The electronic trip unit includes a 20-minute thermal memory, so the breaker remembers prior heating after a trip and re-closes with a shorter allowable cool-down — useful for motor or transformer feeders that see repeated start cycles. The LCD display and ammeter measurement give local readout of phase currents without an external meter, which speeds commissioning and fault finding.

This MCCB delivers 85 kA Icu at 220/240 V AC, 70 kA at 380/415 V, 65 kA at 440 V, 50 kA at 500/525 V, and 42 kA at 660/690 V AC. For a 415 V distribution board, the 70 kA Icu is the figure to coordinate with upstream fuses or a higher-rated breaker — selectivity tables from Schneider will show whether this H-rated frame clears a downstream fault before the main trips.

Fixed-mount backplate installation with 70 mm connection pitch. Dimensions: 327 mm high, 210 mm wide, 147 mm deep. IP40 enclosure protection (IK07 impact resistance) means it can be installed in a clean indoor panel without additional sealing. The manually operated control with LCD display and four red fault-indication LEDs plus one yellow overload LED provides local status without opening the panel door.

Electrical durability: 2000 cycles at 690 V In, 4000 at In/2; 5000 cycles at 440 V In, 6000 at In/2. Mechanical durability: 10,000 cycles. Operating altitude 0–2000 m without derating, 2000–5000 m with derating. Relative humidity 0–95 %. No earth-leakage protection built in — add a Vigi module if ground-fault detection is required.

Frequently asked questions

How do I get current pricing and availability for C080H35AFM?

The C080H35AFM is sourced to order against an RFQ through independent distribution. Submit a request for quote to confirm current pricing and availability.

What is the breaking capacity of C080H35AFM at 415 V?

70 kA Icu at 380/415 V AC, 50/60 Hz, per IEC 60947-2. This is the H breaking capacity code rating.

What protection functions does the MicroLogic 5.0 A trip unit provide?

L (long-time overload protection), S (short-time short-circuit protection), and I (instantaneous short-circuit protection). The trip unit is electronic with a 20-minute thermal memory.

What are the mounting dimensions of C080H35AFM?

327 mm high, 210 mm wide, 147 mm deep. Fixed backplate mount with 70 mm connection pitch. Front connection both upside and downside.