Skip to main content
Schneider Electric C100H42AFM — Miniature Circuit Breakers (MCB)

Schneider Electric C100H42AFM ComPacT NS 1000A 4P MCCB, 70kA

MPNC100H42AFM
Active

Schneider Electric ComPacT NS new generation, MCCB, 1000 A at 50 °C, 70 kA Icu at 415 V AC, MicroLogic 2.0 A trip unit, 4 poles, fixed mount, IP40.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C100H42AFM — Identification
ParameterValue
Product nameComPacT NS new generation
Product rangeComPacT
Product range (series)ComPacT NS630b...1600 new generation
Product/component typeCircuit breaker
Device applicationDistribution
C100H42AFM — Ratings
ParameterValue
Rated current (In)1000 A at 50 °C
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)52 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 52 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 48 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 31 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory B
Overvoltage categoryIII
C100H42AFM — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)2000 cycles at 690 V In 4000 cycles at 690 V In/2 5000 cycles at 440 V In 6000 cycles at 440 V In/2
Mechanical durability (cycles)10000 cycles
C100H42AFM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeManually operated
Local signalling/indication4 LEDs (red) for fault indication 1 LED (yellow) for overload
C100H42AFM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
Relative humidity0...95 %
C100H42AFM — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C100H42AFM — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.4...1 x In
Trip unit protection functionsLI

Product details

MCCB for distribution — 1000 A, MicroLogic 2.0 A, 4P

The Schneider Electric C100H42AFM is a ComPacT NS new generation moulded-case circuit breaker rated 1000 A at 50 °C, with a MicroLogic 2.0 A electronic trip unit providing L (long-time overload) and I (instantaneous short-circuit) protection. The 4-pole, fixed-mount format with front connections suits backplate installation in switchboards where space is planned around a 280 mm width and 327 mm height.

Rated 85 kA Icu at 240 V AC, 70 kA at 415 V, 65 kA at 440 V, 50 kA at 500 V, and 42 kA at 690 V — all per IEC 60947-2. The H breaking capacity code (70 kA at 415 V) means this breaker coordinates well downstream of a higher-rated upstream device, keeping fault energy contained.

Fixed mount on a backplate, 70 mm connection pitch, front upside and downside connections. The 4-pole format with neutral on the left matches standard panel layout practice.

Frequently asked questions

What are the key ratings of the C100H42AFM?

Rated 1000 A at 50 °C, 70 kA Icu at 415 V AC (IEC 60947-2), MicroLogic 2.0 A electronic trip unit with L and I protection, 4 poles, fixed mount, IP40.

Where can I buy the C100H42AFM?

Sourced to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

What standards does the C100H42AFM comply with?

Designed and tested to EN/IEC 60947-2 for low-voltage switchgear and controlgear. Pollution degree 3, overvoltage category III, and IK07 impact rating also apply.

MPN