Schneider Electric C100H450FM — Miniature Circuit Breakers (MCB)

Schneider Electric C100H450FM ComPacT NS 1000A 4P MCCB, 85kA

MPNC100H450FM
Active

Schneider Electric ComPacT NS new generation, C100H450FM, 4P fixed MCCB, 1000 A, MicroLogic 5.0 electronic trip unit, 85 kA Icu at 240 V AC, EN/IEC 60947-2.

$5,473.81Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C100H450FM — Identification
ParameterValue
Product nameComPacT NS new generation
Product rangeComPacT
Product range (series)ComPacT NS630b...1600 new generation
Product/component typeCircuit breaker
Device applicationDistribution
C100H450FM — Ratings
ParameterValue
Rated current (In)1000 A at 50 °C
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)52 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 52 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 48 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 31 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory B
Overvoltage categoryIII
C100H450FM — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)2000 cycles at 690 V In 4000 cycles at 690 V In/2 5000 cycles at 440 V In 6000 cycles at 440 V In/2
Mechanical durability (cycles)10000 cycles
C100H450FM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeManually operated
Local signalling/indication4 LEDs (red) for fault indication 1 LED (yellow) for overload
C100H450FM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
Relative humidity0...95 %
C100H450FM — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C100H450FM — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.4...1 x In
Trip unit protection functionsLSI

Product details

The Schneider Electric C100H450FM is a ComPacT NS new generation 4-pole fixed-mounted moulded-case circuit breaker (MCCB) carrying a MicroLogic 5.0 electronic trip unit rated 1000 A at 50 °C. It is a manually operated distribution breaker built to EN/IEC 60947-2, Category B (full selectivity capable). The H breaking capacity code means 85 kA Icu at 220/240 V AC, 70 kA at 380/415 V, and 42 kA at 660/690 V — figures that govern fault-clearing at the main or feeder level in a 50/60 Hz network.

The MicroLogic 5.0 provides LSI protection: long-time overload (L), short-time short-circuit (S) with adjustable delay for zone-selective interlocking, and instantaneous (I). The electronic trip unit draws 22 W power loss and maintains a 20-minute thermal memory so re-closing on a hot breaker sees the correct thermal state. Four red LEDs signal fault type; a yellow LED flags overload. No earth-leakage protection is integrated — that would require a separate Vigi module.

Mounting and enclosure fit

Fixed-mount on a backplate, 327 mm high × 280 mm wide × 147 mm deep, with front connection both top and bottom. IP40 enclosure protection and IK07 impact resistance suit indoor switchboard installation; pollution degree 3 per IEC 60947-2 covers the typical factory-floor environment. Neutral is on the left.

Frequently asked questions

What is the breaking capacity of C100H450FM at 415 V?

The breaking capacity code H gives 70 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. At 440 V it is 65 kA; at 690 V it is 42 kA.

MPN
C100H450FM