Schneider Electric C100H460FM — Residual Current Breakers (RCCB/RCBO)

Schneider Electric C100H460FM ComPacT NS 1000A, 85 kA Icu

MPNC100H460FM
Active

Schneider Electric ComPacT NS new generation, C100H460FM, manually operated 4P circuit breaker, 1000 A trip unit rating, MicroLogic 6.0 electronic trip unit, 85 kA Icu at 240 V AC, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C100H460FM — Residual Current Protection
ParameterValue
Trip unit technologyElectronic
Local signalling / indication4 LEDs (red) for fault indication 1 LED (yellow) for overload
C100H460FM — Electrical Ratings
ParameterValue
Rated current (In)1000 A at 50 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz
Number of poles4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Overvoltage categoryIII
Electrical durability2000 cycles at 690 V In 4000 cycles at 690 V In/2 5000 cycles at 440 V In 6000 cycles at 440 V In/2
Mechanical durability (operating cycles)10000 cycles
C100H460FM — Identification
ParameterValue
Product nameComPacT NS new generation
Product / component typeCircuit breaker
Product range / familyComPacT
C100H460FM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeManually operated
C100H460FM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C100H460FM — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The C100H460FM is a Schneider Electric ComPacT NS new generation manually operated circuit breaker, 4 poles, with a 1000 A MicroLogic 6.0 electronic trip unit. It's built for distribution duty in switchboards and panelboards, rated per EN/IEC 60947-2.

Mounts fixed to a backplate — no DIN rail here. The 327 mm height, 280 mm width, and 147 mm depth mean it needs a substantial cutout in the gland plate; plan for the 70 mm connection pitch when laying out bus bars or cable lugs. IP40 enclosure protection keeps out tools and fingers but isn't rated for washdown — install it in a dry, indoor switchboard. Front connections top and bottom simplify bus routing in a lineup. The MicroLogic 6.0 is fully electronic, so no thermal bimetal to drift; the 20-minute thermal memory matches the cooling curve of conductors after a fault.

Mechanical durability is 10,000 cycles — that's the maintenance interval to track. The four red LEDs give fault indication (overload, short circuit, ground fault, etc.) and a yellow LED signals an overload alarm — useful for a technician walking the lineup. Overvoltage category III suits fixed-installation distribution boards.

Frequently asked questions

What is C100H460FM's breaking capacity at 415 V?

The C100H460FM delivers 70 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. That's the H breaking capacity code — suitable for high-fault mains.

What trip unit does the C100H460FM use?

It uses a MicroLogic 6.0 electronic trip unit with LSI+G protection: long-time overload, short-time short-circuit, instantaneous short-circuit, and ground fault. Rated 1000 A at 50 °C.

Where can I buy the C100H460FM?

This part is sourced and quoted to order against an RFQ through independent and authorized distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for the current supply position.

MPN
C100H460FM