Skip to main content
Schneider Electric C10F3TM080 — Miniature Circuit Breakers (MCB)

Schneider Electric C10F3TM080 ComPacT NSX 80A MCCB, 36kA at

MPNC10F3TM080
Active

Schneider Electric, ComPacT NSX, circuit breaker, C10F3TM080, 80 A, 3P, 36 kA Icu at 415 V AC, thermal-magnetic TM-D trip unit.

$153.38 – $442.64Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C10F3TM080 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C10F3TM080 — Ratings
ParameterValue
Rated current (In)80 A at 40 °C
Poles configuration3P
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 25 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
Rated service breaking capacity (Ics)85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C10F3TM080 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical durability (cycles)50000 cycles
C10F3TM080 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C10F3TM080 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C10F3TM080 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C10F3TM080 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The C10F3TM080 is a Schneider Electric ComPacT NSX100F molded case circuit breaker, 3-pole, rated 80 A at 40 °C with a thermal-magnetic TM-D trip unit.

Breaking capacity — what the ratings mean

The breaking capacity is specified per IEC 60947-2 across multiple voltage levels. At 415 V AC — the most common industrial distribution voltage — it delivers 36 kA Icu. At 480 V AC (UL 60947-4-1) it still handles 25 kA. For a 80 A feeder on a 400 V panel with typical transformer sizes, that's ample headroom. The 8 kA at 690 V AC covers the rare high-voltage industrial bus.

Mounts on a backplate, front-connected both sides. The toggle handle provides manual control. The 5 slots accept auxiliary contacts, shunt trips, or alarm switches without additional wiring space.

Durability and electrical life

Rated for 50,000 mechanical cycles and 50,000 electrical cycles at 440 V at rated current. That drops to 30,000 cycles at 440 V at In, and 10,000 cycles at 690 V at In. For a distribution feeder switched a few times a year, that's effectively lifetime. For frequent switching applications like capacitor banks or motor circuits, the thermal-magnetic TM-D trip unit is suitable but the electrical life at lower currents (In/2) extends to 50,000 cycles at 440 V.

Frequently asked questions

What is the breaking capacity of C10F3TM080 at 415 V?

It delivers 36 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2.

What trip unit does C10F3TM080 use?

It uses a thermal-magnetic TM-D trip unit with L (overload) and I (short-circuit) protection, rated 80 A at 40 °C.

Where can I buy C10F3TM080 and how is it quoted?

This part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time.

MPN