Schneider Electric C10H4TM063C — Miniature Circuit Breakers (MCB)

Schneider Electric C10H4TM063C ComPacT NSX100H, 63 A, 70 kA

MPNC10H4TM063C
Active

Schneider Electric ComPacT NSX100H, 4-pole, 63 A, thermal-magnetic TM-D trip unit, 70 kA Icu at 415 V AC, toggle control, backplate mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C10H4TM063C — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C10H4TM063C — Ratings
ParameterValue
Rated current (In)63 A at 50 °C
Poles configuration4P
Breaking capacity100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C10H4TM063C — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical durability (cycles)50000 cycles
C10H4TM063C — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C10H4TM063C — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C10H4TM063C — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C10H4TM063C — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The TM-D provides fixed thermal protection for overloads (L) and fixed magnetic protection for short-circuits (I). For a 400 V distribution panel, that is a solid SCCR anchor for the downstream branch. Rated 63 A at 50 °C, the TM-D trip unit is a fixed-setting thermal-magnetic — no dials to mis-set during commissioning. The breaker carries a 4-pole (4P) configuration with neutral on the left.

Breaking capacity by voltage — the so-what for your fault study

The C10H4TM063C (NSX100H frame) delivers 100 kA Icu at 240 V, 70 kA at 415 V, 65 kA at 440 V, 50 kA at 500 V, 35 kA at 525 V, and 10 kA at 690 V.

Mounting and integration — backplate, front connections

Both line and load connections are front-access, which simplifies busbar routing and panel wiring. IK07 impact rating handles routine panel knocks.

Sourcing — quoted to order against RFQ

This is an active, widely stocked line. No minimum order constraints beyond standard distributor terms.

Frequently asked questions

What is the breaking capacity of C10H4TM063C at 415 V?

70 kA Icu at 380/415 V AC per IEC 60947-2. At 240 V it is 100 kA; at 690 V it is 10 kA.