Schneider Electric C10N6TM050 — Miniature Circuit Breakers (MCB)

Schneider Electric C10N6TM050 ComPacT NSX MCCB, 50 A, 4P, 50

MPNC10N6TM050
Active

Schneider Electric ComPacT NSX, molded case circuit breaker, 4 poles, 50 A thermal-magnetic TM-D trip unit, 50 kA Icu at 415 V AC, toggle control, front connection.

$214.92 – $432.69Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C10N6TM050 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C10N6TM050 — Ratings
ParameterValue
Rated current (In)50 A at 40 °C
Poles configuration4P
Breaking capacity90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 50 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
Rated service breaking capacity (Ics)90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C10N6TM050 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical durability (cycles)50000 cycles
C10N6TM050 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C10N6TM050 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C10N6TM050 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C10N6TM050 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

What you're getting with the C10N6TM050

The Schneider Electric C10N6TM050 is a ComPacT NSX100N molded case circuit breaker (MCCB) with a 50 A thermal-magnetic TM-D trip unit, four poles, and an N-frame breaking capacity of 50 kA Icu at 415 V AC. The thermal-magnetic trip gives you L (overload) protection via a bimetal element and I (short-circuit) protection via a solenoid, both field-adjustable within the trip unit's range.

Breaking capacity — what those numbers mean for your panel

But the full curve matters: 90 kA at 240 V, 50 kA at 440 V, 36 kA at 500 V, 35 kA at 525 V, and 10 kA at 690 V. If your system runs at 480 V (common in North America), the UL listing shows 50 kA Icu at 480 V AC — same as the IEC 415 V figure. The 10 kA at 600/690 V is the weak point: if your fault current at that voltage exceeds 10 kA, step up to an S or H frame. The 50,000-cycle electrical durability at 440 V at half rated current (In/2) and 30,000 cycles at full In gives you a solid service life for a distribution breaker that isn't cycled daily like a motor-starter contactor.

Mounts flat on a backplate — no DIN rail here, so plan for bolt-on or screw-clamp fixing. The 161 mm height by 140 mm width by 86 mm depth fits a standard MCCB cutout. Front connections top and bottom, with a 35 mm connection pitch between poles. Neutral is on the left (3D configuration — no neutral protection, just a solid bar). IK07 impact rating means it survives a tool drop.

Frequently asked questions

What is C10N6TM050's breaking capacity at 480 V?

50 kA Icu at 480 V AC per UL 60947-4-1. The IEC rating at 440 V is also 50 kA, so the breaker performs identically across the 440–480 V band common in North American industrial panels.

What does the TM-D trip unit protect against?

L (overload) via a thermal bimetal element and I (short-circuit) via a magnetic solenoid. It's a fixed-trip thermal-magnetic unit — no electronic adjustment, no ground-fault module. Set the thermal pickup via the dial on the front; the magnetic pickup is factory-set and non-adjustable.

Where can I buy C10N6TM050 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What compliance documentation does this breaker carry?

Designed and tested to EN/IEC 60947-2 for circuit breakers, with UL 60947-4-1 listing for the North American market. Pollution degree 3, overvoltage category III, and suitability for isolation per the same standard. The IP40 front face and IK07 impact rating are per IEC 60529 and IEC 62262 respectively.