Skip to main content
Schneider Electric C10N6TM050C — Miniature Circuit Breakers (MCB)

Schneider Electric C10N6TM050C ComPacT NSX 50A, 50 kA 415V

MPNC10N6TM050C
Active

Schneider Electric ComPacT NSX100N, circuit breaker, 4P, 50 A, TM-D trip unit, 50 kA Icu at 415 V AC, toggle control, IP40.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C10N6TM050C — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C10N6TM050C — Ratings
ParameterValue
Rated current (In)50 A at 50 °C
Poles configuration4P
Breaking capacity90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C10N6TM050C — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical durability (cycles)50000 cycles
C10N6TM050C — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C10N6TM050C — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C10N6TM050C — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C10N6TM050C — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The C10N6TM050C is a Schneider Electric ComPacT NSX100N circuit breaker — a 4-pole, 50 A thermal-magnetic unit from the ComPacT range, built to EN/IEC 60947-2. The TM-D trip unit gives you two protections in one block: thermal overload (L) and magnetic short-circuit (I). At 50 °C it holds a steady 50 A; the N breaking capacity code means it can interrupt 50 kA at 415 V AC — enough for most industrial distribution boards without cascading upstream.

Breaking capacity — what those numbers actually mean for your panel

The C10N6TM050C carries a 90 kA Icu at 240 V AC and 50 kA at 415 V AC. At 690 V the interrupting rating drops to 10 kA, so if your line runs on 690 V distribution, you need to check coordination with the upstream feeder.

Front connections top and bottom — no rear-access requirement, so it fits standard distribution boards. The 140 mm width and 161 mm height leave room for cable glands and busbar take-offs. IP40 front face keeps dust out; IK07 impact rating handles a tool bump during commissioning.

Frequently asked questions

Where can I buy C10N6TM050C and what is the lead time?

The C10N6TM050C is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or lead-time number is published here.

What is the closest alternative to C10N6TM050C in the same family?

Within the ComPacT NSX100N frame, the closest alternative would be a unit with the same NSX100N frame and TM-D trip but a different amp rating — for example, a 63 A version (C10N6TM063C) if your load needs headroom, or a 40 A version (C10N6TM040C) if the 50 A is overspecified. The physical footprint, breaking capacity, and terminal layout are identical; only the trip rating changes.

MPN
C10N6TM050C