Schneider Electric C11F4TM032B — Miniature Circuit Breakers (MCB)

Schneider Electric C11F4TM032B ComPacT NSXm 32A 4P MCCB, 36

MPNC11F4TM032B
Active

Schneider Electric ComPacT NSXm, C11F4TM032B, 4P thermal-magnetic MCCB, 32 A at 40 °C, 36 kA at 415 V AC, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11F4TM032B — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11F4TM032B — Ratings
ParameterValue
Rated current (In)32 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11F4TM032B — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C11F4TM032B — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C11F4TM032B — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11F4TM032B — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11F4TM032B — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity85 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
C11F4TM032B — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The 4P configuration with left-side neutral suits panelboards where the neutral is switched and protected alongside the phases.

Service breaking capacity (Ics) is typically 50–75 % of Icu on this class; for repeated fault clearing, confirm the Ics figure in the full coordination tables. Overvoltage category III confirms it is designed for fixed-installation distribution boards, not for downstream equipment-level protection. Suitability for isolation (yes, per IEC 60947-2) means the open contacts provide a visible gap that meets the safety disconnection standard — no separate isolator needed upstream for local maintenance.

The grey RAL 7016 housing is the standard industrial finish for this series. IP40 front-panel protection means it tolerates tools and fingers but not water ingress — keep it behind an IP54 enclosure door in washdown areas. IK07 impact resistance handles accidental tool strikes during panel wiring.

Frequently asked questions

What is the breaking capacity of C11F4TM032B?

The C11F4TM032B has a 36 kA breaking capacity at 415 V AC (performance level F), certified to EN/IEC 60947-2.

What is the closest alternative to C11F4TM032B in the ComPacT family?

Within the same NSXm 63F frame, the closest alternative would be a different trip rating (e.g., 25 A or 40 A) or a different pole configuration — the mechanical footprint and breaking capacity are shared across the frame. No pin-compatible drop-in exists with different ratings; the trip unit is integral to the breaker.

How do I get current pricing and availability for C11F4TM032B?

Submit an RFQ through this listing. The part is sourced to order via independent distribution; current pricing and stock position are confirmed at quote time.

What compliance documentation does Schneider provide for C11F4TM032B?

The breaker carries EN/IEC 60947-2 certification. Schneider typically provides a Declaration of Conformity (CE) and, for this series, UL/CSA recognition files are available on request. RoHS and REACH compliance declarations are standard with the shipment documentation.

MPN
C11F4TM032B