Skip to main content
Schneider Electric C11F4TM100B — Miniature Circuit Breakers (MCB)

Schneider Electric C11F4TM100B ComPacT NSXm MCCB, 100 A, 36

MPNC11F4TM100B
Active

Schneider Electric ComPacT NSXm, 4P MCCB, 100 A thermal-magnetic TM-D trip unit, 36 kA at 415 V AC, IP40, grey (RAL 7016).

$593.24Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11F4TM100B — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11F4TM100B — Ratings
ParameterValue
Rated current (In)100 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)440 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11F4TM100B — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical durability (cycles)20000 cycles
C11F4TM100B — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C11F4TM100B — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11F4TM100B — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11F4TM100B — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity85 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
C11F4TM100B — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The C11F4TM100B is a Schneider Electric ComPacT NSXm 4-pole moulded-case circuit breaker with a 100 A thermal-magnetic TM-D trip unit, rated 36 kA at 415 V AC (performance level F). The thermal-magnetic TM-D trip provides inverse-time overload protection (thermal element) and instantaneous short-circuit protection (magnetic element), so it covers both sustained overloads and hard faults in one device. Rated 100 A at 40 °C, it's sized for 100 A feeder or branch circuits in 50/60 Hz AC networks.

Mounts on a backplate in horizontal or vertical orientation — flat against the panel. The 108 mm width (12 module pitches at 9 mm) and 137 mm height fit standard DIN-rail enclosures; depth is 80 mm. Connection terminals accept compression lugs or busbars, with front-facing upside and downside connections for straightforward panel wiring. Neutral is on the left. Pollution degree 3 (IEC 60664-1) means it's rated for conductive pollution environments typical in industrial control panels — no derating needed for the usual factory-floor dust and humidity (0–95 % RH).

Suitability for isolation is confirmed per that standard — so it can be used as a disconnecting means in the panel. IP40 front face (IK07 impact resistance) keeps dust and accidental tool contact out; not rated for washdown, so keep it in a dry enclosure. Overvoltage category III, suitable for fixed-installation distribution boards.

Frequently asked questions

How do I get current pricing and availability for C11F4TM100B?

Submit an RFQ through this listing. We source the C11F4TM100B through independent distribution and confirm current pricing and availability at quote time.

What is the breaking capacity of C11F4TM100B?

36 kA at 415 V AC (performance level F), which is the standard interrupting rating for this frame size in distribution applications.

What is C11F4TM100B's listed range?

It belongs to the Schneider Electric ComPacT range, specifically the ComPacT NSXm family of moulded-case circuit breakers.

MPN
C11F4TM100B