Skip to main content
Schneider Electric C11F6TM080L — Miniature Circuit Breakers (MCB)

Schneider Electric C11F6TM080L ComPacT NSXm 80A 4P Circuit B

MPNC11F6TM080L
Active

Schneider Electric ComPacT NSXm, circuit breaker, 4P, 80 A at 40 °C, TM-D trip unit, 36 kA 415 V AC, IP40, grey (RAL 7016).

$245.43Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11F6TM080L — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11F6TM080L — Ratings
ParameterValue
Rated current (In)80 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)440 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11F6TM080L — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical durability (cycles)20000 cycles
C11F6TM080L — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C11F6TM080L — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11F6TM080L — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11F6TM080L — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity85 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
C11F6TM080L — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The Schneider Electric C11F6TM080L is a ComPacT NSXm 4-pole circuit breaker with a thermal-magnetic TM-D trip unit rated 80 A at 40 °C. It is designed for distribution applications per EN/IEC 60947-2, with a breaking capacity of 36 kA at 415 V AC (performance level F). The 80 A rating means it protects a 4-wire circuit (three phases plus neutral) up to that continuous current; the 36 kA interrupting rating tells you it can safely clear a fault up to that level without upstream devices needing to intervene — relevant for panel coordination studies.

The 80 A rating is at 40 °C ambient; per IEC 60947-2, derating applies above that temperature. Terminals are Everlink lugs accepting 2.5…95 mm² rigid or stranded aluminium/copper, or 2.5…70 mm² flexible copper. The 4-pole configuration has neutral on the left.

Frequently asked questions

What is C11F6TM080L's breaking capacity?

It has a breaking capacity of 36 kA at 415 V AC (performance level F) per EN/IEC 60947-2.

What terminals does C11F6TM080L use?

It uses Everlink lugs accepting 2.5…95 mm² rigid or stranded aluminium/copper, or 2.5…70 mm² flexible copper.

Where can I buy C11F6TM080L and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
C11F6TM080L