Schneider Electric C11H3TM063L — Miniature Circuit Breakers (MCB)

Schneider C11H3TM063L ComPacT NSXm 63A MCCB, 70kA 415V

MPNC11H3TM063L
Active

Schneider Electric ComPacT NSXm, C11H3TM063L, 3-pole 63 A MCCB, TM-D thermal-magnetic trip, 70 kA at 415 V AC, IP40, grey (RAL 7016).

$195.21Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11H3TM063L — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11H3TM063L — Ratings
ParameterValue
Rated current (In)63 A at 40 °C
Poles configuration3P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11H3TM063L — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C11H3TM063L — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches9 module
C11H3TM063L — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11H3TM063L — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11H3TM063L — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
C11H3TM063L — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The 63 A frame sits in the NSXm family, so it shares the compact 81 mm wide, 137 mm tall footprint and backplate mounting with the rest of the range.

For a 400 V distribution board with a transformer rating that pushes prospective short-circuit current into the 50–65 kA range, the H performance level gives headroom. Termination uses Everlink lugs: 2.5–95 mm² rigid or stranded aluminium/copper, or 2.5–70 mm² flexible copper. That covers everything from a 16 mm² branch feeder up to a 70 mm² main riser in one lug. The 9-module pitch (9 x 9 mm = 81 mm width) is standard for DIN-rail enclosures, though the breaker mounts to a backplate, not the rail itself. IK07 impact resistance handles accidental tool strikes during commissioning.

Electrical durability is rated 20,000 cycles at 440 V In/2 and 10,000 cycles at 440 V In; mechanical durability is 20,000 cycles. That is typical for a distribution MCCB — not a switching duty cycle, but adequate for infrequent manual switching and fault clearing. The breaker is certified for isolation per IEC 60947-2 (a visible gap when open), so it doubles as a disconnect without a separate switch. Power dissipation is 5.7 W per pole at rated current — about 17 W total for the 3-pole unit. That matters for enclosure thermal rise calculations when several breakers are ganged in a small panel.

Frequently asked questions

What is the breaking capacity of C11H3TM063L?

It is rated 70 kA at 415 V AC (performance level H), which is the Icu breaking capacity per IEC 60947-2.

What terminals does this MCCB use?

Everlink lugs accepting 2.5–95 mm² rigid or stranded aluminium/copper, and 2.5–70 mm² flexible copper.

Where can I buy C11H3TM063L and how is it quoted?

This part is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time, not listed here.