Skip to main content
Schneider Electric C11N6TM063B — Miniature Circuit Breakers (MCB)

Schneider Electric C11N6TM063B ComPacT NSXm, 63A 4P Thermal-

MPNC11N6TM063B
Active

Schneider Electric ComPacT NSXm, C11N6TM063B, 4P thermal-magnetic circuit breaker, 63 A at 40 °C, 50 kA at 415 V AC, grey (RAL 7016).

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11N6TM063B — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11N6TM063B — Ratings
ParameterValue
Rated current (In)63 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11N6TM063B — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (cycles)20000 cycles
C11N6TM063B — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C11N6TM063B — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11N6TM063B — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11N6TM063B — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity90 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity90 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
C11N6TM063B — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

What it is and what it does

The C11N6TM063B is a Schneider Electric ComPacT NSXm moulded-case circuit breaker, 4-pole, with a thermal-magnetic TM-D trip unit rated 63 A at 40 °C. It is designed for distribution applications and carries a 50 kA breaking capacity at 415 V AC (performance level N). That rating means it can safely interrupt a fault current up to 50 kA without welding or rupturing — critical for panel coordination where the upstream transformer can deliver high short-circuit current.

Key ratings and what they mean for fit

Rated 63 A at 40 °C ambient. If your panel ambient runs higher, derate per the thermal curve — the TM-D trip unit is temperature-sensitive. The 50 kA at 415 V AC SCCR is the maximum fault it can clear; verify that your available fault current at the breaker's location does not exceed that figure. The 4-pole version (4P) switches all three phases plus neutral, with the neutral on the left. Suitability for isolation is confirmed per IEC 60947-2, so it can be used as a disconnecting means in the panel. Mechanical durability is 20,000 cycles; electrical durability varies with load — 20,000 cycles at 440 V at half rated current, 10,000 cycles at full rated current. That is typical for a distribution breaker; not intended for frequent switching duty like a contactor.

Mounting and integration

Mounts on a backplate (not DIN rail), in horizontal or vertical orientation, flat on the back. The 9 mm pitch footprint is 12 modules wide — 108 mm width, 137 mm height, 80 mm depth. Connection is front-facing via compression lugs or busbars; pitch is 35 mm with spreaders, 27 mm without. IP40 front face, IK07 impact resistance. Pollution degree 3 per IEC 60664-1 means it is rated for industrial environments with conductive pollution.

Frequently asked questions

What is the breaking capacity of C11N6TM063B?

The performance level is N, rated 50 kA at 415 V AC. That is the maximum short-circuit current it can safely interrupt at that voltage.

What compliance documentation does this brand provide for C11N6TM063B?

The breaker is certified to EN/IEC 60947-2 and carries suitability for isolation per that standard. Pollution degree 3 per IEC 60664-1. Specific RoHS/REACH/UL declarations are available from the manufacturer upon request.

Where can I buy C11N6TM063B?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm response.

MPN