Schneider Electric C11N6TM100B — Miniature Circuit Breakers (MCB)

Schneider Electric C11N6TM100B ComPacT NSXm 100A 4P 50kA MCC

MPNC11N6TM100B
Active

Schneider Electric ComPacT NSXm, C11N6TM100B, 4P 100 A TM-D thermal-magnetic MCCB, 50 kA at 415 V AC, EN/IEC 60947-2, grey (RAL 7016).

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11N6TM100B — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11N6TM100B — Ratings
ParameterValue
Rated current (In)100 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)440 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11N6TM100B — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical durability (cycles)20000 cycles
C11N6TM100B — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches12 module
C11N6TM100B — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11N6TM100B — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11N6TM100B — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity90 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity90 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
C11N6TM100B — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

Above that temperature, derate per the IEC 60947-2 thermal curve — a panel running at 50 °C will need a higher-rated frame or active cooling to hold the same load. Category A utilisation means this breaker is not intended for selective coordination with downstream devices — it trips instantaneously on short-circuit. For selective (Category B) coordination, step up to the ComPacT NSX or NT range. Overvoltage category III means it is rated for fixed-installation distribution boards, not for equipment-level protection. No electronic adjustments, no ground-fault module. Straightforward replacement for existing TM-D breakers.

Mounts on a backplate in horizontal or vertical orientation. The 9-module pitch (12 modules at 9 mm each = 108 mm wide) and 137 mm height fit standard distribution panel cutouts. Front connections top and bottom accept compression lugs or busbars. The grey RAL 7016 colour is the standard industrial finish.

Frequently asked questions

What is the breaking capacity of C11N6TM100B?

50 kA at 415 V AC, performance level N. That is the maximum short-circuit current it can safely interrupt at that voltage.

What standards does this MCCB comply with?

EN/IEC 60947-2 for low-voltage switchgear and controlgear. It also carries suitability for isolation per that standard.