Skip to main content
Schneider Electric C16H3TM125C — Miniature Circuit Breakers (MCB)

Schneider Electric C16H3TM125C ComPacT NSX 160H, 125A, 3P, 1

MPNC16H3TM125C
Active

Schneider Electric ComPacT NSX 160H, thermal-magnetic circuit breaker, 125 A, 3-pole, 100 kA Icu at 240 V AC, TM-D trip unit.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C16H3TM125C — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C16H3TM125C — Ratings
ParameterValue
Rated current (In)125 A at 50 °C
Poles configuration3P
Breaking capacity100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C16H3TM125C — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical durability (cycles)40000 cycles
C16H3TM125C — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C16H3TM125C — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C16H3TM125C — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C16H3TM125C — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

ComPacT NSX 160H — 125 A thermal-magnetic, 3-pole

It is a 3-pole (3P) device, breaking capacity code H, delivering 100 kA Icu at 220/240 V AC, 70 kA at 380/415 V, and 65 kA at 440 V, all per IEC 60947-2. The frame is NSX160H, so the breaker accepts plug-in trip units and auxiliary modules through its 5 accessory slots.

At 415 V, the 70 kA Icu rating places this breaker in the H category — high enough for most distribution panels downstream of a transformer. For a 125 A feeder, the 10.78 W dissipation per pole stays manageable inside a standard IP40 enclosure.

The C16H3TM125C is listed as current production. No official successor has been issued — this remains the active order code for a 125 A TM-D in the NSX160H frame.

Front connections both upside and downside. Pitch between poles is 35 mm. IK07 impact resistance and IP40 front face handle typical enclosure environments.

Frequently asked questions

What is the breaking capacity of C16H3TM125C at 415 V?

70 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2.

What compliance documentation does Schneider Electric provide for C16H3TM125C?

The breaker is certified to EN/IEC 60947-2 and carries IEC 60664-1 pollution degree 3 and IEC 62262 IK07 impact rating. RoHS and REACH declarations are standard with the brand's industrial circuit breakers.

Where can I buy C16H3TM125C?

The C16H3TM125C is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN