Schneider Electric ComPacT NSX, NSX400HB1, 3P, 400 A at 40 °C, 85 kA Icu at 500 V AC, MicroLogic 5.3 E electronic trip unit, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C40V35E400 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C40V35E400 — Ratings
ParameterValue
Rated current (In)400 A at 40 °C
Poles configuration3P
Breaking capacity85 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 80 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 75 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)85 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 80 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 75 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C40V35E400 — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)12000 cycles at 440 V In/2 6000 cycles at 440 V In 6000 cycles at 690 V In/2 3000 cycles at 690 V In
Mechanical durability (cycles)15000 cycles
C40V35E400 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C40V35E400 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C40V35E400 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C40V35E400 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range160...400 A
Trip unit protection functionsLSI

Product details

MCCB for distribution panels — 400 A, 85 kA at 500 V

The C40V35E400 is a Schneider Electric ComPacT NSX400HB1 moulded-case circuit breaker, 3-pole, rated 400 A at 40 °C with a MicroLogic 5.3 E electronic trip unit. It delivers 85 kA Icu at 500 V AC 50/60 Hz per EN/IEC 60947-2, putting it in the HB1 breaking-capacity class — enough for high-fault industrial distribution without cascading upstream. Backplate-mounted, front-connected, toggle-operated with an LCD display for metering and event logs.

Trip unit and protection logic

The MicroLogic 5.3 E provides L (long-time overload), S (short-time short-circuit), and I (instantaneous short-circuit) protection, plus energy metering and power-quality data. The electronic trip unit is field-adjustable; the LCD display shows ready status, overload pre-alarm at 90 % Ir (orange) and 105 % Ir (red).

IP40 front face (IK07 impact) suits clean indoor panels — not washdown.

Frequently asked questions

What is C40V35E400's breaking capacity at 690 V?

75 kA Icu at 660/690 V AC 50/60 Hz per IEC 60947-2.

What compliance standards does C40V35E400 meet?

It complies with EN/IEC 60947-2, pollution degree 3 per IEC 60664-1, IP40 per IEC 60529, and IK07 per IEC 62262.

Where can I buy C40V35E400 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

MPN
C40V35E400