Skip to main content
Schneider Electric EZC250H44063 — Circuit Breaker Accessories

Schneider Electric EZC250H44063 EasyPact EZC250H, 63 A, 4P,

MPNEZC250H44063
Obsolete

Schneider Electric EasyPact EZC250H, EZC250H44063, 63 A thermal-magnetic molded case circuit breaker, 4 poles, 25 kA Icu at 440 V AC, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EZC250H44063 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC250H44063 — Electrical
ParameterValue
Network type (AC/DC)AC DC
Rated current [In]63 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description4P
EZC250H44063 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating63 A at 50 °C
Trip unit nameTM-D
Protection typeShort-circuit protection Overload protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability10000 cycles
Local signallingPositive contact indication
EZC250H44063 — Mechanical
ParameterValue
Connection pitch35 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC250H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width140 mm
Height165 mm
Depth60 mm
EZC250H44063 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC250H44063 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 GB/T 14048.2 EN/IEC 60947-1 JIS C8201-2-2

Product details

The Schneider Electric EZC250H44063 is a 4-pole EasyPact EZC250H molded case circuit breaker with a thermal-magnetic TM-D trip unit rated 63 A at 50 °C.

Breaking capacity — what the H code delivers

The H breaking capacity code means this breaker delivers 25 kA Icu at 440 V AC and 36 kA at 380–415 V AC. At 220–240 V AC it jumps to 85 kA Icu. For DC circuits, it handles 30 kA at 125 V DC (1-pole) and the same at 250 V DC (2-pole). The 10 kA Icu at 550 V AC is the ceiling — if your system voltage sits above 480 V, that's the number for fault-current coordination. For a 480 V distribution panel with an available fault current of, say, 22 kA, this breaker lands comfortably inside its envelope.

Fixed mounting on a backplate with front-front connections — the line and load conductors both terminate on the front face, which keeps the wiring plane accessible and avoids reaching behind the breaker. IP20 finger-safe protection is adequate for enclosed panels; the IK07 impact rating means the front cover withstands a 2 J hammer blow — useful if tools get dropped during commissioning.

Certified to EN/IEC 60947-2, GB/T 14048.2, EN/IEC 60947-1, and JIS C8201-2-2. Category A utilization covers distribution circuits without intentional short-time delay; for motor branch circuits requiring selectivity with downstream breakers, verify the instantaneous trip threshold against the load inrush.

Frequently asked questions

What is the breaking capacity of EZC250H44063 at 440 V?

25 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2. At 380–415 V AC it rises to 36 kA Icu.