Schneider Electric EZC250H44080 — Circuit Breaker Accessories

Schneider Electric EZC250H44080 EasyPact EZC250H 80A 4P Circ

MPNEZC250H44080
Obsolete

Schneider Electric EasyPact EZC250H, 4-pole thermal-magnetic MCCB, 80 A, 85 kA Icu at 240 V AC, TM-D trip unit, toggle control, fixed mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EZC250H44080 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC250H44080 — Electrical
ParameterValue
Network type (AC/DC)DC AC
Rated current [In]80 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description4P
EZC250H44080 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating80 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability10000 cycles
Local signallingPositive contact indication
EZC250H44080 — Mechanical
ParameterValue
Connection pitch35 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC250H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width140 mm
Height165 mm
Depth60 mm
EZC250H44080 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC250H44080 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 JIS C8201-2-2 EN/IEC 60947-2 GB/T 14048.2

Product details

What this breaker delivers

The Schneider Electric EZC250H44080 is a 4-pole EasyPact EZC250H moulded-case circuit breaker rated 80 A at 40 °C, with a thermal-magnetic TM-D trip unit. It carries an 85 kA Icu at 220–240 V AC — enough to handle high-fault utility feeds in distribution panels — and still delivers 36 kA at 380–415 V AC and 25 kA at 440 V AC. The 80 A rating at 50 °C tells you the breaker is thermally compensated for elevated panel ambient; if your enclosure runs cooler, the continuous current can be pushed to the 40 °C rating. The 690 V rated insulation voltage and 550 V AC / 250 V DC operational voltage cover most industrial distribution voltages up to 480/277 V systems, plus DC bus applications.

Fixed backplate mounting with front-facing connections — both line and load sides terminate on the same plane, which simplifies bus-bar layout and gland-plate planning. Connection pitch is 35 mm, matching common bus-bar spacing. IP20 finger-safe terminals and IK07 impact resistance mean the breaker can be mounted in a lockable enclosure without additional shrouding for routine touch protection.

Protection and compliance

Compliance covers EN/IEC 60947-1, EN/IEC 60947-2, JIS C8201-2-2, and GB/T 14048.2 — the key standards for acceptance in European, Japanese, and Chinese installations. No earth-leakage or neutral protection built in; those functions require an external module or a different variant.

Frequently asked questions

What is the breaking capacity of the EZC250H44080 at 240 V?

85 kA Icu at 220–240 V AC 50/60 Hz per IEC 60947-2. At 440 V it drops to 25 kA, and at 550 V to 10 kA.

Where can I buy the EZC250H44080?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Does the EZC250H44080 include earth-leakage protection?

No, it ships without earth-leakage protection. The TM-D trip unit covers overload and short-circuit only.