Skip to main content
Schneider Electric EZC250H44100 — Circuit Breaker Accessories

Schneider EasyPact EZC250H44100 MCCB, 100A, 85kA at 240V

MPNEZC250H44100
Obsolete

Schneider Electric EasyPact EZC250H, EZC250H44100, 4-pole MCCB, 100 A TM-D trip unit, 85 kA Icu at 240 V AC, 10 kA at 550 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EZC250H44100 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC250H44100 — Electrical
ParameterValue
Network type (AC/DC)DC AC
Rated current [In]100 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description4P
EZC250H44100 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating100 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability10000 cycles
Local signallingPositive contact indication
EZC250H44100 — Mechanical
ParameterValue
Connection pitch35 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC250H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width140 mm
Height165 mm
Depth60 mm
EZC250H44100 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC250H44100 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 JIS C8201-2-2 GB/T 14048.2 EN/IEC 60947-1

Product details

It belongs to the EasyPact EZC250H series, a compact distribution breaker line for commercial and light industrial panelboards. The H breaking-capacity code means it handles 85 kA Icu at 220–240 V AC — enough for high-fault service-entrance positions — and still delivers 10 kA Icu at 550 V AC, so it covers 480Y/277 V distribution without a current-limiting fuse upstream.

The TM-D trip unit gives you fixed thermal (overload) and magnetic (short-circuit) protection curves, no interchangeable rating plugs. At 100 A and 40 °C ambient, it carries the full rated current; the 50 °C rating is the same 100 A, so no derating is needed in a warm enclosure. At 480 V (380–415 V class), the 36 kA Icu still covers most commercial services. DC ratings are 30 kA Icu at 125 V DC (single-pole) and 30 kA Icu at 250 V DC (two poles in series) — useful for battery-bank or UPS distribution, but note the 2-pole series connection requirement for 250 V DC.

Physical integration and environment

Fixed mounting on a backplate, front-connected both line and load sides. IP20 finger-safe terminals and IK07 impact resistance mean it is protected against accidental contact and light mechanical shock inside the panel.

No earth-leakage protection built in — that is a separate module if needed.

Frequently asked questions

What is the breaking capacity of this breaker at different voltages?

The EZC250H44100 delivers 85 kA Icu at 220–240 V AC, 36 kA at 380–415 V AC, 25 kA at 440 V AC, and 10 kA at 550 V AC. For DC, it provides 30 kA Icu at 125 V DC (1-pole) and 30 kA at 250 V DC (2-pole series).

Where can I buy the EZC250H44100 and how is it quoted?

The EZC250H44100 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What standards does the EZC250H44100 comply with?

It complies with EN/IEC 60947-2, JIS C8201-2-2, and GB/T 14048.2. It is also suitable for isolation per IEC 60947-2.

MPN