Schneider Electric EZC250H44200 — Circuit Breaker Accessories

Schneider Electric EZC250H44200 EasyPact EZC250H Circuit Bre

MPNEZC250H44200
Obsolete

Schneider Electric EasyPact EZC250H series, molded case circuit breaker, EZC250H44200, 200 A rated current, 4 poles, thermal-magnetic TM-D trip unit, breaking capacity code H.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EZC250H44200 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC250H44200 — Electrical
ParameterValue
Network type (AC/DC)AC DC
Rated current [In]200 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description4P
EZC250H44200 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating200 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability10000 cycles
Local signallingPositive contact indication
EZC250H44200 — Mechanical
ParameterValue
Connection pitch35 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC250H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width140 mm
Height165 mm
Depth60 mm
EZC250H44200 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC250H44200 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 GB/T 14048.2 EN/IEC 60947-2 JIS C8201-2-2

Product details

The Schneider Electric EZC250H44200 is a 4-pole molded case circuit breaker from the EasyPact EZC250H series, rated 200 A at 40 °C with a thermal-magnetic TM-D trip unit. The TM-D trip provides both overload and short-circuit protection in a single, non-interchangeable unit — fixed-trip breakers like this are specified when the protection setting is locked at the factory and no field adjustment is needed, which suits distribution panels where the load is known and stable. The 'H' breaking capacity code means this breaker is rated for high fault levels: 85 kA Icu at 220–240 V AC, 36 kA at 380–415 V AC, and 25 kA at 440 V AC. At 550 V AC it still interrupts 10 kA.

Mounting and integration into a panel

The 140 mm width and 165 mm height fit standard distribution panel cutouts; depth is 60 mm. Connection pitch is 35 mm, matching common busbar and lug spacing for panel wiring. IP20 finger-safe protection on the front; IK07 impact resistance means it withstands a 2 J hammer blow — enough for accidental tool drops during panel work but not rated for washdown environments. Positive contact indication (red/green flag on the toggle) gives a visual confirmation of contact position independent of the handle mechanism — useful during commissioning and troubleshooting when the panel door is open.

Standards compliance covers IEC 60947-1, IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2. The breaker is certified for isolation per IEC 60947-2, meaning it can be used as a disconnecting means with a visible break — important for lockout/tagout procedures on distribution feeders.

Frequently asked questions

How do I get current pricing and availability for the EZC250H44200?

Submit an RFQ through this listing. Pricing and lead time are confirmed at quote time through independent distribution channels; no stock count or price is published here.

What is the breaking capacity of the EZC250H44200 at 240 V?

85 kA Icu at 220–240 V AC 50/60 Hz per IEC 60947-2. At 380–415 V it is 36 kA, and at 440 V it is 25 kA.

Does the EZC250H44200 include earth-leakage protection?

No. The trip unit is thermal-magnetic only (TM-D) with no integral earth-leakage module. Earth-leakage protection requires an external add-on or a separate RCCB downstream.

What compliance documentation does Schneider provide for the EZC250H44200?

The breaker is certified to IEC 60947-1, IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2. It carries an IP20 rating and IK07 impact protection. RoHS and REACH declarations are available from Schneider Electric's documentation portal.