Schneider Electric GV3P651 — Miniature Circuit Breakers (MCB)

Schneider Electric GV3P651 TeSys Deca Motor Circuit Breaker,

MPNGV3P651
Active

Schneider Electric TeSys Deca GV3P651, motor circuit breaker, 3-pole, 65 A rated current, thermal-magnetic, 100 kA breaking capacity at 240 V AC.

$233.95Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

GV3P651 — Identification
ParameterValue
Product nameTeSys GV3
Product rangeTeSys Deca
Product/component typeMotor circuit breaker
Device applicationMotor protection
GV3P651 — Ratings
ParameterValue
Rated current (In)65 A
Poles configuration3P
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage (Ui)690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz conforming to IEC 60947-2
Utilisation categoryCategory A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1
GV3P651 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Suitability for isolationYes conforming to IEC 60947-1
Electrical durability (cycles)50000 cycles for AC-3 at 415 V In
Mechanical durability (cycles)50000 cycles
GV3P651 — Mechanical
ParameterValue
Control typeRotary handle
Terminal tightening torque5 N.m - on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
GV3P651 — Environmental
ParameterValue
Operating ambient temperature-20...60 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to IEC 60529
GV3P651 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-1:Clause 30.2 IEC/EN 60335-2-40:Annex JJ
GV3P651 — Electrical
ParameterValue
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2

Product details

It combines a thermal-magnetic trip unit — the thermal element adjustable from 48 to 65 A per IEC 60947-2 — with a magnetic fixed trip set at 910 A. That magnetic threshold clears short-circuits fast enough to protect the downstream contactor and cable; the thermal curve handles overloads. It is designed for motor protection in AC networks at 50/60 Hz. Rated operational voltage is 690 V AC, with a breaking capacity of 100 kA Icu at 230/240 V, 50 kA at 400/415 V, and 6 kA at 690 V. That means at a 400 V industrial supply it can interrupt a 50 kA fault without welding its contacts — sufficient for most secondary distribution panels. The utilisation category is AC-3 per IEC 60947-4-1, so it is rated for switching squirrel-cage motors under load. It also carries Category A per IEC 60947-2 for selective coordination in a breaker lineup. Motor power ratings are 30 kW at 400/415 V, 45 kW at 500 V, and 55 kW at 690 V. Phase-failure sensitivity is built in per IEC 60947-4-1, so it will trip on a lost phase before the motor single-phases to destruction. It is also suitable for isolation per IEC 60947-1 — meaning you can safely use it as a visible-break disconnect for the motor circuit.

Mounting position can be horizontal or vertical, which gives flexibility in a crowded enclosure. The control is a rotary handle, so the breaker can be manually switched without opening the door. IP20 per IEC 60529 means finger-safe terminals; IK09 impact resistance means the enclosure can survive a 10 J blow from a tool drop. Climatic withstand conforms to IACS, so it is suitable for marine and humid environments. Screw-clamp terminals accept the motor and line cables; tightening torque is 5 N·m. Power dissipation per pole is 8 W at rated current — three poles total 24 W. That heat must be considered in the enclosure thermal calculation, especially if the breaker is enclosed in a small glanded box.

Compliance documentation is extensive: the breaker is certified to EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and IEC/EN 60335-1 Clause 30.2 and IEC/EN 60335-2-40 Annex JJ. That UL and CSA listing covers North American installations; the IEC certifications cover European and global markets. Fire resistance is tested to 960 °C per IEC 60695-2-11. Operating altitude is rated to 3000 m without derating.

Durability and mechanical robustness

Electrical durability is 50,000 cycles under AC-3 at 415 V at rated current. Mechanical durability is also 50,000 cycles. That is a solid service life for a motor starter that cycles several times per shift. The breaker is rated for uninterrupted duty per IEC 60947-4-1, so it can carry rated current continuously without derating. Mechanical robustness: the contactor-open state withstands 15 Gn shocks for 11 ms; contactor-closed withstands 30 Gn for 11 ms. Vibration resistance is 4 Gn from 5 to 300 Hz. That makes it suitable for installation on machinery with vibration, such as compressors or conveyors.

Frequently asked questions

What is the closest alternative to the GV3P651 in the same family?

The GV3P651 is the 65 A thermal-magnetic variant in the TeSys Deca range. The closest sibling is the GV3P65, which shares the same 65 A frame but uses a different trip unit configuration. The GV3P651 has the adjustable thermal protection range of 48 to 65 A and a fixed magnetic trip at 910 A, while the GV3P65 may have a fixed thermal setting. Verify the specific trip curve and adjustment range for your application before substituting.

What are the key ratings of the GV3P651?

Rated current is 65 A, adjustable thermal protection from 48 to 65 A, magnetic trip fixed at 910 A. Breaking capacity is 100 kA Icu at 240 V, 50 kA at 415 V, 12 kA at 500 V, 6 kA at 690 V. Rated operational voltage is 690 V AC. Motor power ratings are 30 kW at 400/415 V, 45 kW at 500 V, 55 kW at 690 V. Utilisation category is AC-3 for motor switching.

What compliance certifications does the GV3P651 carry?

The GV3P651 is certified to EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and IEC/EN 60335-1 Clause 30.2 and IEC/EN 60335-2-40 Annex JJ. It also conforms to IACS for climatic withstand and IEC 60695-2-11 for fire resistance at 960 °C.