Skip to main content
Schneider Electric LC2K16107M72 — Contactors

Schneider TeSys K LC2K16107M72 reversing contactor, 16 A AC-

MPNLC2K16107M72
Obsolete

Schneider Electric TeSys K reversing contactor, LC2K16107M72, 3P, AC-3 ≤440 V 16 A, 1 NO, 220…230 V AC, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC2K16107M72 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K16107M72 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-3
LC2K16107M72 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K16107M72 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K16107M72 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

Product overview

It carries an AC-3 utilization category rated at 16 A up to 440 V and 220…230 V AC coil, meaning it switches three-phase squirrel-cage motors within that current envelope — the rating that governs real motor starting duty, not a resistive-load figure.

Frequently asked questions

What are the key ratings for this reversing contactor?

It is a 3-pole reversing contactor rated AC-3 at 16 A up to 440 V, with a 220…230 V AC coil. It includes one normally open auxiliary contact and is preassembled with a reversing power busbar. IP20 finger-safe protection, V1 flame retardance per UL 94.

What compliance documentation does this part carry?

The contactor is certified IP20 per VDE 0106, flame retardance V1 per UL 94, and also meets NF F 16-101 and NF F 16-102 Requirement 2 for rail applications. Mechanical shock and vibration ratings are documented per IEC 60068-2-27 and IEC 60068-2-6.

MPN
LC2K16107M72