Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 16 A, 1 NO auxiliary, 440 V AC coil, preassembled with reversing power busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC2K16107R7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K16107R7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-3
LC2K16107R7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K16107R7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K16107R7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric LC2K16107R7 is a TeSys K reversing contactor, 3-pole, rated 16 A in AC-3 utilisation category at ≤440 V with a 440 V AC coil. It comes preassembled with the reversing power busbar, so you don't have to wire the mechanical and electrical interlock yourself — it's a drop-in reversing starter for a three-phase motor up to that current. That's the number that governs real motor control applications — not the AC-1 resistive rating.

Mechanical and environmental robustness

Rated for 10 Gn shock on Y and Z axes (contactor closed) and 15 Gn on Y and Z (contactor opened), per IEC 60068-2-27. Vibration resistance is 4 Gn closed, 2 Gn opened across 5–300 Hz. That's enough for most industrial machinery and mobile equipment applications, including conveyors, pumps, and compressors mounted on a machine frame. Protective treatment conforms to IEC 60068 and DIN 50016 for corrosion resistance — relevant for humid or mildly aggressive atmospheres in food-and-bev or wastewater plants.

Frequently asked questions

What are the key ratings for this reversing contactor?

It is a 3-pole reversing contactor rated 16 A in AC-3 duty at ≤440 V, with a 440 V AC coil. It includes one normally-open auxiliary contact and comes preassembled with the reversing power busbar.

What is the closest alternative to the LC2K16107R7 in the TeSys K family?

Within the same TeSys K series, the non-reversing equivalent is the LC1K16107R7 — same coil voltage, same 16 A AC-3 rating, but without the reversing busbar or mechanical interlock. For a reversing application, the LC2K16107R7 is the pre-assembled solution; you would otherwise need two LC1K contactors plus a separate mechanical interlock (LA9K) and busbar kit.

MPN