Skip to main content
Schneider Electric LC2K1610FC72 — Contactors

Schneider TeSys K LC2K1610FC72 reversing contactor, 16 A, 12

MPNLC2K1610FC72
Active

Schneider Electric TeSys K reversing contactor, 3P, AC-3 <=440 V 16 A, 1 NO, 127 V AC coil, preassembled with reversing power busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC2K1610FC72 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K1610FC72 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-3
LC2K1610FC72 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K1610FC72 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K1610FC72 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric LC2K1610FC72 is a TeSys K reversing contactor — a 3-pole, 3 NO power pole unit rated for AC-3 duty at 16 A up to 440 V, with a 127 V AC coil and one built-in NO auxiliary contact. It ships preassembled with the reversing power busbar, so you skip the mechanical interlock wiring and busbar assembly step on the panel bench. The AC-4 rating covers plugging and inching duty, where the contactor breaks stalled-rotor current. For a reversing pair, AC-4 is the tougher cycle; this contactor carries both categories. The coil pulls 127 V AC — common in North American control transformers and older European panels. IP20 finger-safe terminals per VDE 0106 keep the panel builder out of trouble during commissioning.

The protective treatment (TC per IEC 60068 and DIN 50016) indicates the contactor has passed a damp-heat cyclic test — relevant if the panel sees condensation or high-humidity environments. No special coating or conformal coating is listed beyond this standard treatment.

Frequently asked questions

What are the key ratings I need to check for fit?

The headline rating is AC-3 <=440 V at 16 A for motor switching. The coil is 127 V AC. Power circuit rated operational voltage is 690 V AC 50/60 Hz. It has one NO auxiliary contact built in. Dimensions: 90 mm wide, 58 mm tall, 57 mm deep.

Does this reversing contactor come with the busbar preassembled?

Yes, the device presentation is 'Preassembled with reversing power busbar'. That means the mechanical interlock and the power busbar linking the two contactors are already fitted — you mount it as one unit on the DIN rail.

MPN
LC2K1610FC72