Skip to main content
Schneider Electric LC2K16107Q7 — Contactors

Schneider TeSys K LC2K16107Q7 Reversing Contactor, 3P, 16 A,

MPNLC2K16107Q7
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 16 A, 1 NO, coil 380-400 V AC, preassembled with reversing power busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC2K16107Q7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K16107Q7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-4
LC2K16107Q7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K16107Q7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K16107Q7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric LC2K16107Q7 is a TeSys K reversing contactor — 3-pole, rated AC-3 ≤440 V at 16 A, with a single NO auxiliary contact and a 380-400 V AC coil. It ships preassembled with the reversing power busbar, so the kit is complete for a forward-reverse motor starter without hunting for loose cross-bus parts. The AC-3 rating (16 A at ≤440 V) governs motor switching — inrush and break of a squirrel-cage induction motor up to roughly 7.5 kW at 400 V. The AC-4 category also listed means it can handle plugging and inching duty, where the contactor opens under full locked-rotor current.

Altitude derating starts above 2000 m.

Flame retardance rated V1 per UL 94, also compliant with NF F 16-101 and NF F 16-102. Protective treatment meets IEC 60068 and DIN 50016 for corrosion resistance. Mechanical robustness tested to 10 Gn shock on Y and Z axes (contactor closed) per IEC 60068-2-27.

Frequently asked questions

What is the closest alternative to LC2K16107Q7?

No official successor order code is recorded in the lifecycle data. A parametric match would need a TeSys K or TeSys D reversing contactor with the same pole count, AC-3 current rating (16 A at ≤440 V), and 380-400 V AC coil — but pin-compatibility and busbar fit must be verified against the existing panel layout.

What are the key ratings of LC2K16107Q7?

3-pole reversing contactor, AC-3 rated 16 A at ≤440 V, AC-4 rated, coil 380-400 V AC, one NO auxiliary contact. Preassembled with reversing power busbar. Dimensions 90 x 58 x 57 mm.

MPN
LC2K16107Q7