Skip to main content
Schneider Electric LC2K1610D72 — Contactors

Schneider Electric LC2K1610D72 TeSys K Reversing Contactor,

MPNLC2K1610D72
Active

Schneider Electric TeSys K reversing contactor, 3P, AC-3 <=440 V 16 A, 1 NO, 36 V AC coil, preassembled with reversing power busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC2K1610D72 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K1610D72 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-3
LC2K1610D72 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K1610D72 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K1610D72 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The LC2K1610D72 is a TeSys K reversing contactor from Schneider Electric — a 3-pole unit rated for AC-3 duty at 16 A up to 440 V, with a 36 V AC coil and one normally open auxiliary contact. It comes preassembled with the reversing power busbar, so you don't need to build the interlock wiring yourself; that's one less step in the panel. The AC-3 rating (16 A at ≤440 V) means it's sized for starting and stopping squirrel-cage motors under load — the standard utilisation category for motor contactors. The 36 V AC coil is a control-voltage common in older or safety-isolated circuits; verify your transformer taps before wiring.

Flame retardance meets UL 94 V1 and NF F 16-101/102, so it's acceptable for rail and transit applications where fire-smoke-toxicity requirements apply. Operating altitude is 2000 m without derating; above that, you'll need to factor in air-density cooling loss.

Because it's a current TeSys K part, cross-referencing to a different frame or coil voltage is straightforward within the same family — but the reversing busbar is pre-assembled here, so swapping to a non-reversing variant would lose that integration.

Frequently asked questions

What are the key ratings for this reversing contactor?

It's a 3-pole reversing contactor rated AC-3 at 16 A up to 440 V, with a 36 V AC coil and one NO auxiliary contact. The power circuit is rated for 690 V AC 50/60 Hz. IP20 protected, UL 94 V1 flame retardant.

What compliance documentation does this part carry?

The contactor meets UL 94 V1 flame retardance, NF F 16-101/102 for rail fire safety, and IP20 per VDE 0106. It's also tested for shock and vibration per IEC 60068-2-27 and IEC 60068-2-6.

MPN
LC2K1610D72