Skip to main content
Schneider Electric LC2K1610FE7 — Contactors

Schneider TeSys K LC2K1610FE7 Reversing Contactor, 3P, 16A A

MPNLC2K1610FE7
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 16 A, 1 NO, 115 V AC coil, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC2K1610FE7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K1610FE7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-4
LC2K1610FE7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K1610FE7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K1610FE7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The 16 A rating at ≤440 V AC covers small reversing loads like conveyors or fan direction changeovers. The 115 V AC coil suits North American control-voltage panels.

Lifecycle reality

Schneider lists this part as obsolete. No official successor is recorded in the product lifecycle data.

AC-3 at 16 A means it switches three-phase squirrel-cage motors up to that current during starting and running — typical for a 7.5 kW motor at 400 V. The 115 V AC coil pull-in voltage is around 85 V; dropout below about 55 V. IP20 finger-safe terminals suit enclosed panel mounting; no washdown rating here. The 57 mm depth fits standard 90 mm wide DIN-rail contactor footprints.

Frequently asked questions

What is the closest alternative to LC2K1610FE7?

No official successor is recorded in the lifecycle data. A parametric replacement would need to match the 3-pole reversing contactor form, 16 A AC-3 rating, and 115 V AC coil — but no pin-compatible drop-in is named by Schneider.

What are the key ratings of LC2K1610FE7?

3-pole reversing contactor, AC-3 utilisation category, rated 16 A at ≤440 V AC, with a 115 V AC coil and one normally-open auxiliary contact. IP20 protection.

MPN