The Schneider Electric LC2K1610F72 is a TeSys K reversing contactor — a 3-pole unit rated for AC-3 duty at 16 A up to 440 V, with a 110 V AC coil and one normally open auxiliary contact. It comes preassembled with the reversing power busbar, so you don't have to wire the mechanical interlock and power crossover yourself. The AC-3 rating means it's built for starting and stopping squirrel-cage motors — the 16 A figure at 440 V covers motors up to roughly 7.5 kW in that voltage class. The AC-4 rating also covers inching and plugging duty, so it handles reversing applications where the motor sees full-voltage reversal under load. Rated operational voltage goes up to 690 V AC 50/60 Hz on the power circuit, giving headroom for 480 V or 600 V systems. The 110 V AC coil is common in North American control transformers.
Schneider LC2K1610F72 TeSys K Reversing Contactor, 3P, 16 A
Schneider Electric TeSys K reversing contactor, LC2K1610F72, 3P, AC-3 <= 440 V 16 A, 1 NO, 110 V AC coil, preassembled with reversing power busbar.
Specifications
| Parameter | Value |
|---|---|
| Product / component type | Reversing contactor |
| Series / range | TeSys |
| Application | Motor control |
| Parameter | Value |
|---|---|
| Rated operational voltage (Ue) | Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit |
| Utilisation category | AC-3 AC-4 |
| Parameter | Value |
|---|---|
| Pole configuration | 3P |
| Parameter | Value |
|---|---|
| IP degree of protection | IP20 conforming to VDE 0106 |
| Operating altitude | 2000 m without derating |
| Mechanical robustness | Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
| Protective treatment / pollution degree | TC conforming to IEC 60068 TC conforming to DIN 50016 |
| Flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
| Parameter | Value |
|---|---|
| Width | 90 mm |
| Height | 58 mm |
| Depth | 57 mm |
Product details
Frequently asked questions
What are the key ratings for the LC2K1610F72?
Three poles, AC-3 utilisation category at 16 A up to 440 V, AC-4 rating for reversing duty, 110 V AC coil, one NO auxiliary contact, rated operational voltage 690 V AC 50/60 Hz on the power circuit.
What compliance documentation does this contactor carry?
Flame retardance V1 per UL 94, plus NF F 16-101 and 16-102 for rail. Protective treatment TC per IEC 60068 and DIN 50016. IP20 per VDE 0106. Mechanical shock and vibration tested per IEC 60068-2-27 and 60068-2-6.