Skip to main content
Schneider Electric LP2K12004MD3 — Contactors

Schneider TeSys K LP2K12004MD3 Changeover Contactor, 220 VDC

MPNLP2K12004MD3
Obsolete

Schneider Electric TeSys K series, LP2K12004MD3 changeover contactor, 4-pole, 220 V DC coil, AC-1 rated 20 A, preassembled with reversing power busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LP2K12004MD3 — Identification
ParameterValue
Product / component typeChangeover contactor
Series / rangeTeSys
ApplicationResistive load
LP2K12004MD3 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz
Utilisation categoryAC-1
LP2K12004MD3 — Contacts & Poles
ParameterValue
Pole configuration4P
LP2K12004MD3 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP2K12004MD3 — Approvals
ParameterValue
StandardsVDE 0660 NF C 63-110 IEC 60947 BS 5424
LP2K12004MD3 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The Schneider TeSys K LP2K12004MD3 is a 4-pole changeover contactor — a reversing contactor pair mechanically interlocked so both main contacts cannot close simultaneously. It ships preassembled with the reversing power busbar, which saves panel-build time wiring the interlock and power loop between the two contactors. The control circuit is 220 V DC, with a built-in bidirectional peak-limiting diode suppressor across the coil. That suppressor handles the inductive kick from the DC coil, so you do not need an external flyback diode on the control wiring. Rated in AC-1 utilisation category for resistive loads, the contactor carries 20 A continuously (Ith) with a power-circuit impedance of 3 mOhm at 50 Hz. Heat dissipation is 3 W at 20 °C coil temperature.

The AC-1 rating (20 A at ≤440 V) governs resistive loads — heaters, incandescent lamps, resistive banks. For motor or inductive loads you would need the AC-3 rating, which this listing does not carry; this part is selected for switching resistive circuits where the inrush is low and the breaking current is close to the continuous current. Rated breaking capacity is 110 A at 440 V, 80 A at 500 V, and 70 A at 660–690 V per IEC 60947. Mechanical durability is 5 million cycles; electrical durability is 300,000 cycles at 20 A AC-1. Mounts on rail or plate. Screw-clamp terminals accept up to 4 mm² solid or 2.5 mm² flexible with ferrule.

Changeover contactors of this class are used in control panels for reversing motor starters (forward/reverse), dual-speed motor switching, or source transfer between two supplies. The mechanical interlock prevents a phase-to-phase short if both contactors close simultaneously.

Approvals include IEC 60947, VDE 0660, NF C 63-110, BS 5424, UL 508, CSA C22.2 No 14, and UL 94 V1 flame retardance. The part also carries B10d reliability data per EN/ISO 13849-1 for safety-related control systems.

Frequently asked questions

What is the closest alternative to LP2K12004MD3 in the TeSys K family?

Within the TeSys K range, the LP2K series includes variants with different coil voltages and pole configurations. The LP2K12004MD3 is a 4-pole changeover contactor with a 220 V DC coil. A direct sibling would share the same 4-pole mechanical interlock and reversing busbar but differ in coil voltage — for example, a 24 V DC or 110 V DC version. The choice depends on the control voltage available in your panel.

What compliance documentation does Schneider provide for LP2K12004MD3?

The part carries approvals to IEC 60947, VDE 0660, NF C 63-110, BS 5424, UL 508, and CSA C22.2 No 14. It also meets UL 94 V1 flame retardance and has B10d reliability data per EN/ISO 13849-1. Standard Schneider documentation includes a datasheet, installation manual, and declaration of conformity covering these standards.

MPN
LP2K12004MD3