Skip to main content
Schneider Electric LP2K12013ED — Contactors

Schneider TeSys K LP2K12013ED Reversing Contactor, 3P, 12A A

MPNLP2K12013ED
Obsolete

Schneider Electric TeSys K reversing contactor, LP2K12013ED, 3-pole, AC-3 ≤440 V 12 A, 1 NC auxiliary, 48 V DC coil, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LP2K12013ED — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control Resistive load
LP2K12013ED — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-1 AC-4 AC-3
LP2K12013ED — Contacts & Poles
ParameterValue
Pole configuration3P
LP2K12013ED — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP2K12013ED — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

Rated AC-3 duty at 12 A up to 440 V, it handles the forward/reverse direction switching typical of conveyor drives, pump sets, and small hoists. The 48 V DC coil draws from a control transformer or DC supply; the 1 NC auxiliary contact provides a feedback path for the safety circuit or PLC input.

The AC-3 rating at 12 A is the motor-switching current — the value that governs real-world contactor life when starting and stopping induction motors under load. AC-4 (inching/plugging) and AC-1 (resistive) are also listed, so the same part covers heater banks or frequent jogging if derated appropriately. The 48 V DC coil is a specific control voltage; verify your panel's DC supply matches before committing the BOM line. IP20 finger-safe protection (per VDE 0106) means the contactor is safe for open-panel mounting but not for washdown environments.

Schneider has marked the LP2K12013ED as obsolete. No official successor order code appears, so a direct drop-in replacement from the same series is not confirmed. For a B.

Altitude derating kicks in above 2000 m. Vibration resistance is 4 Gn closed (5–300 Hz) and 2 Gn open; shock ratings are 15 Gn closed on Z axis. These numbers matter if the panel is mounted on a moving platform or near heavy rotating machinery.

Frequently asked questions

What are the key ratings for fit?

AC-3 motor-switching current is 12 A at ≤440 V. The coil is 48 V DC. It has 3 power poles (all NO) and 1 NC auxiliary contact. Rated operational voltage for the power circuit is 690 V AC 50/60 Hz.

What compliance documentation is available?

The part carries IP20 protection per VDE 0106, flame retardance V1 per UL 94, and protective treatment per IEC 60068 and DIN 50016. Mechanical robustness is tested to IEC 60068-2-27 (shock) and IEC 60068-2-6 (vibration).

MPN