Skip to main content
Schneider Electric LP2K12017BD — Contactors

Schneider TeSys K LP2K12017BD reversing contactor, 3P, 12 A

MPNLP2K12017BD
Active

Schneider Electric TeSys K reversing contactor, LP2K12017BD, 3 poles, AC-3 ≤ 440 V 12 A, 1 NC auxiliary, 24 V DC coil, preassembled with reversing power busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LP2K12017BD — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationResistive load Motor control
LP2K12017BD — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-4 AC-1
LP2K12017BD — Contacts & Poles
ParameterValue
Pole configuration3P
LP2K12017BD — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP2K12017BD — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric TeSys K LP2K12017BD is a 3-pole reversing contactor rated for AC-3 duty at 12 A up to 440 V, with a 24 V DC coil and one normally-closed auxiliary contact. The 24 V DC coil means it drops into a 24 VDC control circuit common in modern panels; verify your control transformer and power supply can deliver the inrush without sag. The 3 NO power poles and 1 NC auxiliary give you one feedback contact for status monitoring or interlocking.

DIN-rail-mountable reversing contactor for motor control panels or conveyor reversing stations. Mechanical robustness is specified for shock and vibration per IEC 60068-2-27 and IEC 60068-2-6, with the contactor closed handling 15 Gn on Z axis for 11 ms and vibration up to 4 Gn at 5–300 Hz. That's enough for most industrial machinery but not for high-shock applications like press lines without additional isolation.

V1 flame retardance per UL 94, plus NF F 16-101 and NF F 16-102 compliance. Protective treatment conforms to IEC 60068 and DIN 50016.

Frequently asked questions

What are the key ratings that decide fit for this reversing contactor?

The critical rating is AC-3 ≤ 440 V at 12 A — that's the motor-switching current for starting and stopping induction motors under load. The 24 V DC coil voltage must match your control circuit. The contactor has 3 NO power poles and 1 NC auxiliary contact. Dimensions are 90 mm wide × 58 mm high × 57 mm deep for DIN-rail mounting.

Does this contactor come with the reversing busbar?

Yes, the LP2K12017BD is described as preassembled with a reversing power busbar, so it's ready to wire into a reversing starter circuit without ordering a separate busbar kit.

What compliance documentation is available for the LP2K12017BD?

The contactor carries a V1 flame retardance rating per UL 94 and complies with NF F 16-101 and NF F 16-102 for railway fire-smoke-toxicity. Protective treatment conforms to IEC 60068 and DIN 50016. The record does not list RoHS or REACH declarations explicitly, so verify with your Schneider documentation package for your specific compliance needs.

MPN