Specifications

LP2K12017ED — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control Resistive load
LP2K12017ED — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-1 AC-3
LP2K12017ED — Contacts & Poles
ParameterValue
Pole configuration3P
LP2K12017ED — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP2K12017ED — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

It carries a 48 V DC coil and one NC auxiliary contact. Rated AC-3 at 12 A up to 440 V, it handles reversing duty on small three-phase motors — think conveyors, pumps, or fan drives where direction change is part of the cycle. The AC-1 rating covers resistive loads at the same current level. The contactor is rated for 690 V AC 50/60 Hz on the power circuit and carries IP20 finger protection per VDE 0106, so it's intended for enclosed panel mounting — not exposed washdown areas.

Frequently asked questions

What are the key ratings for the LP2K12017ED?

It is a 3-pole reversing contactor rated AC-3 at 12 A up to 440 V, with a 48 V DC coil and one NC auxiliary contact. The power circuit is rated for 690 V AC 50/60 Hz.

What is the physical size of the LP2K12017ED?

It measures 90 mm wide, 58 mm high, and 57 mm deep, with IP20 finger protection for enclosed panel mounting.

How do I source the LP2K12017ED if it's obsolete?

Submit an RFQ. We can search independent and surplus channels for available units. There is no official successor order code from Schneider Electric, so a direct manufacturer replacement is not documented.