Schneider Electric LP2K1201ZD3 TeSys K Reversing Contactor,

MPNLP2K1201ZD3
Active

Schneider Electric TeSys K reversing contactor, LP2K1201ZD3, 3P, AC-3 12 A at 440 V, 20 VDC coil, 1 NC auxiliary contact, preassembled with reversing busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LP2K1201ZD3 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control Resistive load
LP2K1201ZD3 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-4 AC-1
LP2K1201ZD3 — Contacts & Poles
ParameterValue
Pole configuration3P
LP2K1201ZD3 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP2K1201ZD3 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

It switches three-phase motor loads in both directions — forward and reverse — through a single contactor pair, which is the standard arrangement for a reversing starter without a separate mechanical interlock.

A 12 A AC-3 contactor typically pairs with a motor full-load current around 9-10 A to allow for inrush. The 20 VDC coil pulls in on a 24 VDC nominal supply; dropout voltage will be lower, so verify the control voltage stays above the dropout threshold under load. Altitude derating kicks in above 2000 m — at 3000 m the dielectric strength and current-carrying capacity need a reduction per IEC 60947. Below that, no adjustment is needed.

Frequently asked questions

What are the key ratings that determine fit?

The headline rating is AC-3 motor-switching current: 12 A at 440 V. The coil is 20 VDC. The contactor is a 3-pole reversing type with 1 NC auxiliary contact, preassembled with the reversing busbar.

What is the IP rating and what does it mean for installation?

IP20 per VDE 0106, which means finger-safe but not sealed against dust or water. It is intended for mounting inside an enclosed control panel, not in washdown or outdoor locations.

What compliance documentation does this part carry?

Flame retardance V1 per UL 94, plus compliance with NF F 16-101 and NF F 16-302 for rail applications. Protective treatment TC per IEC 60068 and DIN 50016 for tropicalized environments.