Schneider Electric LX1G4SBEEA

Schneider LX1G4SBEEA TeSys Contactor Coil, 24-48 V AC/DC

MPNLX1G4SBEEA
Active

Schneider Electric TeSys series, contactor coil LX1G4SBEEA, 4 poles, 24...48 V AC/DC control circuit, built-in bidirectional peak limiting, IP20.

$421.28Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

LX1G4SBEEA key specifications
ParameterValue
Product or component typeContactor coil
Coil voltage24...48 V AC/DC 50/60 Hz
Control circuit voltage limitsOperational 0.8...1.1 Uc 140 °F (60 °C)) Drop-out 0...0.45 Uc 140 °F (60 °C))
Poles description4P
IP degree of protectionIP20 IEC 60529
Connections - terminalsControl circuit push-in termination 1 0.0003...0.004 in² (0.2...2.5 mm²) solid stranded without cable end sleeve AWG 26...AWG 12 Control circuit push-in termination 1 0.0004...0.004 in² (0.25...2.5 mm²) flexible with cable end sleeve AWG 24...AWG 14 Control circuit push-in termination 2 0.0008...0.002 in² (0.5...1.0 mm²) rigid or stranded with cable end sleeve AWG 20...AWG 18
Pollution degree3 IEC 60947-1
Operating altitude9842.52 ft (3000 m) without derating 5000 m with derating factor
Depth3.7 in (93.0 mm)
Width7.3 in (185.0 mm)
Height6.6 in (167.0 mm)
Mechanical durability5 Mcycles

All specifications

LX1G4SBEEA additional specifications
ParameterValue
StandardsEN/IEC 60947-4-1 UL 60947-4-1A CSA C22.2 No 60947-4-1
RangeTeSys
CategoryUS10I1222328
Operating time20...35 ms opening 40...55 ms closing
Coil technologyBuilt-in bidirectional peak limiting
Quantity per set1
Device short nameLX1G
Maximum operating rate600 cyc/mn 140 °F (60 °C)
Electromagnetic compatibilityEMC immunity conforming to IEC 60947-4-1 Emission tests criteria A conforming to IEC 60947-4-1 Immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to SEMI F47
Ambient air temperature for storage-76...176 °F (-60...80 °C)
Ambient air temperature for operation-13...140 °F (-25...60 °C)
Permissible ambient air temperature around the device-40...158 °F (-40...70 °C) at Uc

Product details

What This Coil Is For

The LX1G4SBEEA is the replacement coil for a Schneider TeSys 4-pole contactor. It pulls in on 24 to 48 V AC/DC, and the built-in bidirectional peak limiting handles the snubbing itself — you don't need an external R-C or varistor across the coil. Rated for 5 million mechanical cycles, and it'll cycle up to 600 times a minute at 140 °F (60 °C) ambient. That's a lot of opening and closing before the coil gives up. Opening time runs 20 to 35 ms, closing 40 to 55 ms — consistent enough for sequence timing on a motor starter or reversing circuit.

Compliance is covered: the coil meets EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1. Pollution degree 3 for dirty panels, and it holds a SEMI F47 immunity rating for voltage dips – good for semiconductor fab gear.

Physical footprint: 6.6 in high, 7.3 in wide, 3.7 in deep – it sits where the TeSys frame expects it. AWG 26 to 12 for solid, AWG 24 to 14 for flexible with ferrule. Operating temperature range is -13 to 140 °F (-25 to 60 °C); storage down to -76 °F (-60 °C). If you're mounting it up high where the ambient creeps near 158 °F (70 °C), the coil can still hold at rated control voltage.

Frequently asked questions

What is the control voltage range?

The coil operates on 24 to 48 V AC/DC (50/60 Hz). It pulls in at 0.8 to 1.1 Uc and drops out below 0.45 Uc at 140 °F (60 °C).

What standards does it comply with?

It meets EN/IEC 60947-4-1, UL 60947-4-1A, CSA C22.2 No 60947-4-1, and EMC immunity per IEC 60947-4-1 with test level 20 V/m for radiated interference.