Schneider Electric MGN25135 — Miniature Circuit Breakers (MCB)

Schneider Electric MGN25135 C60H MCB, 40 A, 3P, D Curve, 30

MPNMGN25135
Obsolete

Schneider Electric Multi9 C60H series, MGN25135, 3-pole miniature circuit breaker, 40 A rated, D tripping curve, 30 kA breaking capacity at 240 V AC, thermal-magnetic, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGN25135 — Identification
ParameterValue
Product nameC60
Product rangeMulti9
Product range (series)C60
Product/component typeMiniature circuit-breaker
Device applicationDistribution
MGN25135 — Ratings
ParameterValue
Rated current (In)40 A at 50 °C conforming to EN/IEC 60947-2
Poles configuration3P
Number of protected poles3
Breaking capacity30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2
Rated service breaking capacity (Ics)15 kA 50 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
Rated operational voltage (Ue)440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
MGN25135 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)10000 cycles conforming to EN/IEC 60947-2
Mechanical durability (cycles)20000 cycles
MGN25135 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Control typeToggle
Terminal connection typeTunnel type terminals1.5...35 mm² flexible without cable end Tunnel type terminals1.5...35 mm² flexible with cable end Tunnel type terminals1.5...35 mm² rigid
Terminal tightening torquePower circuit: 3.5 N.m
Wire stripping lengthPower circuit: 14 mm
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width54 mm
Height81 mm
Depth73 mm
Number of 9 mm pitches6
MGN25135 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
Pollution degree3 conforming to EN/IEC 60947-2
MGN25135 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The Schneider Electric MGN25135 is a C60H miniature circuit breaker from the Multi9 range, rated 40 A at 50 °C with a D tripping curve. This is the part to specify when you need high inrush immunity for motor or transformer branch circuits — the D curve holds through starting surges that would nuisance-trip a C curve.

At 415 V it derates to 15 kA Icu, and at 440 V to 10 kA Icu — so in a 400/415 V panel, coordination with an upstream device (typically a 50 kA or 65 kA molded-case breaker) is needed to keep the Ics within the 7.5 kA service rating. The D curve magnetic trip is fixed at 12 x In ±20 %, meaning instantaneous trip between 384 A and 576 A for a 40 A breaker. That suits motor starting, welding equipment, or transformer inrush where the peak draw exceeds 8–10 x In for a few cycles.

The 73 mm depth leaves clearance in standard 100 mm deep enclosures. Tunnel terminals accept 1.5 to 35 mm² rigid or flexible conductors; torque to 3.5 N·m on the power circuit.

Suitable for isolation (full disconnect rating). Earth-leakage protection requires a separate Vigi block — not integrated.

Frequently asked questions

Where can I buy MGN25135 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the D curve on this MCB for?

The D curve magnetic trip is set at 12 x In ±20 %, so it holds through high inrush currents from motors, transformers, or welding equipment without nuisance tripping.

What is the breaking capacity at 415 V?

At 415 V AC the Icu is 15 kA, and the Ics (service breaking capacity) is 7.5 kA (50 % of Icu).

What compliance standards does MGN25135 meet?

It is certified to EN/IEC 60947-2, with IP20 finger protection, pollution degree 3, and suitability for isolation.

MPN
MGN25135