Schneider Electric MGN25138 — Miniature Circuit Breakers (MCB)

MGN25138 C60H MCB, 1A D Curve 4P, 30kA Breaking

MPNMGN25138
Obsolete

Schneider Electric C60H Multi9 miniature circuit breaker, MGN25138, 1A rated current, D curve, 4 poles, 30 kA breaking capacity at 240 V AC, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGN25138 — Identification
ParameterValue
Product nameC60
Product rangeMulti9
Product range (series)C60
Product/component typeMiniature circuit-breaker
Device applicationDistribution
MGN25138 — Ratings
ParameterValue
Rated current (In)1 A at 50 °C conforming to EN/IEC 60947-2
Poles configuration4P
Number of protected poles4
Breaking capacity30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2
Rated service breaking capacity (Ics)15 kA 50 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
Rated operational voltage (Ue)440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
MGN25138 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)10000 cycles conforming to EN/IEC 60947-2
Mechanical durability (cycles)20000 cycles
MGN25138 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Control typeToggle
Terminal connection typeTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Terminal tightening torquePower circuit: 2 N.m
Wire stripping lengthPower circuit: 14 mm
Contact position indicatorYes
Local signalling/indicationON/OFF indication
Width72 mm
Height81 mm
Depth73 mm
Number of 9 mm pitches8
MGN25138 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
Pollution degree3 conforming to EN/IEC 60947-2
MGN25138 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The MGN25138 is a C60H miniature circuit breaker from the Multi9 range, rated 1 A at 50 °C with a D tripping curve. Breaking capacity is 30 kA Icu at 240 V AC, 15 kA at 415 V, and 10 kA at 440 V, all phase-to-phase per EN/IEC 60947-2. The 30 kA rating at 240 V covers high-fault panelboards in commercial and light industrial distribution; the 10 kA at 440 V is the limiting figure for three-phase 400 V systems. Service breaking capacity (Ics) is 50 % of Icu at each voltage level. Four protected poles (4P) switch all phases and neutral in a single 72 mm wide module. The thermal-magnetic trip unit combines a bimetal for overloads and a solenoid for short-circuits — no auxiliary power needed.

Snaps onto 35 mm symmetrical DIN rail (EN 60715) in a fixed mounting position. The 72 mm width occupies 8 x 9 mm pitches, so plan for 8 module spaces in a distribution board. Depth is 73 mm — check gland plate clearance if the panel is shallow. IP20 finger-safe front, suitable for enclosed panels. The toggle actuator gives local ON/OFF indication with a visible contact position indicator for safe isolation verification.

Rated for 10,000 electrical cycles and 20,000 mechanical cycles per EN/IEC 60947-2, which aligns with typical panel life in distribution duty. The separate earth-leakage block option (Vigi C60) allows add-on RCD protection without replacing the breaker.

Frequently asked questions

What is the breaking capacity of MGN25138?

30 kA Icu at 240 V AC, 15 kA at 415 V AC, and 10 kA at 440 V AC, all phase-to-phase per EN/IEC 60947-2. Service breaking capacity (Ics) is 50 % of these values.

What is the D curve and why does it matter?

The D curve trips magnetically at 12 x In (±20 %), meaning it handles high inrush currents from motors and transformers without nuisance tripping — suited for distribution circuits with inductive loads.

Where can I buy MGN25138?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the physical size of MGN25138?

72 mm wide (8 x 9 mm pitches), 81 mm high, 73 mm deep. Mounts on 35 mm DIN rail.