Schneider Electric VW3A4610 — AC Drive (VFD) 480V

Schneider VW3A4610 Passive Filter, 180 A, 400 V, Obsolete

MPNVW3A4610
Obsolete

Schneider Electric Altivar VW3A4610 passive filter, 180 A rated current, 400 V AC, 3-phase, for harmonic reduction on ATV61 / ATV71 drives.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

VW3A4610 — Identification
ParameterValue
Product typePassive filter

Input / Supply

VW3A4610 — Input / Supply
ParameterValue
Rated supply voltage range400 V +/- 10 %
Network number of phases3 phases

Mechanical & Cooling

VW3A4610 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP20

Environmental

VW3A4610 — Environmental
ParameterValue
Operating ambient temperature40...55 °C (with current derating 3 % per °C) 5...40 °C (without current derating)
Operating altitude> 1000...4000 m with current derating 5 % per 1000 m
Relative humidity5...85 % without condensation
Storage / transport temperature-25...55 °C

Product details

Passive harmonic filter for Altivar drives — 180 A, 400 V

The Schneider VW3A4610 is a passive filter designed to reduce current harmonics from Altivar variable speed drives. It is rated 180 A continuous at 400 V +/- 10 % three-phase, and delivers a THDI of 10 % when paired with an ATV61HC11N4 or ATV71HC11N4 motor drive at 110 kW / 150 hp. Efficiency runs at 98 %, with power factor correction that varies by load: unity (1) at 150 % of line current, 0.99 at full load, and 0.85 at 75 % load. Maximum peak current handling is 1.5 times nominal.

Installation and environmental limits

Electrical connection uses bare wires with 12.5 mm diameter. One filter per drive is required for the listed ATV61 and ATV71 models. Ambient operating range is 5 to 40 °C without derating; from 40 to 55 °C derate current by 3 % per °C. Above 1000 m altitude, derate an additional 5 % per 1000 m. Storage temperature spans -25 to 55 °C with 5 to 85 % relative humidity, non-condensing.

The VW3A4610 is classified as obsolete by Schneider Electric.

Frequently asked questions

Where can I buy VW3A4610 and get a price?

The VW3A4610 is available through independent distribution channels. Submit an RFQ for current availability and pricing — confirmed at quote time.

What is the THDI of VW3A4610 with a 110 kW drive?

THDI is 10 % when paired with an ATV61HC11N4 or ATV71HC11N4 motor drive at 110 kW / 150 hp.

What is the power factor correction range of VW3A4610?

Cos phi is 1 at 150 % of line current, 0.99 at 100 % load, and 0.85 at 75 % load.

MPN
VW3A4610