Schneider Electric VW3A46102A — AC Drive (VFD) 480V

Schneider VW3A46102A Passive Filter, 12.5 A, 380-480 V, for

MPNVW3A46102A
Active

Schneider Electric Easy Altivar 610 passive filter, VW3A46102A, 12.5 A output, 380-480 V, 5.5 kW/7.5 hp, 50 Hz, THDI 10 %, efficiency 98 %, thermal losses 129 W.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

VW3A46102A — Identification
ParameterValue
Product typePassive filter

Input / Supply

VW3A46102A — Input / Supply
ParameterValue
Rated supply voltage range380...480 V - 10...10 %
Network number of phases3 phases

Mechanical & Cooling

VW3A46102A — Mechanical & Cooling
ParameterValue
IP degree of protectionIP20 (enclosure mounting)

Environmental

VW3A46102A — Environmental
ParameterValue
Operating ambient temperature-25...45 °C (without current derating)
Storage / transport temperature-25...85 °C storage in original packaging

Approvals

VW3A46102A — Approvals
ParameterValue
Standards complianceUL 61800-5-1 IEC 61800-5-1

Other specifications

VW3A46102A — Other specifications
ParameterValue
THDI10 % for variable speed drive ATV610
Efficiency98 %
Thermal losses129 W
Quantity per drive1 filter per drive for variable speed drive ATV610 motor: 5.5 kW/7.5 hp
Current8.1 A for input 12.5 A for output
Electrical connectionL1, L2, L3, L1', L2', L3' terminal, connection capacity: 0.5...6 mm² D1, D2, D3, D1', D2', D3' terminal, connection capacity: 1.5 mm² TS, TS' terminal, connection capacity: 0.5...4 mm²
Power supply frequency50 Hz +/- 2 %
Electrical insulation classClass N

Product details

The Schneider Electric VW3A46102A is a passive filter for the Easy Altivar 610 variable speed drive, sized for a 5.5 kW / 7.5 hp motor on a 380–480 V three-phase supply. It bolts between the drive and the line — one filter per drive, no sharing. The headline number here is the THDI: 10 % at rated load, which means it knocks the input current distortion down to a level that keeps harmonics off the shared bus. That matters when the drive shares a transformer with other loads or when the plant has a THD cap from the utility.

The filter is rated 8.1 A input / 12.5 A output — the output side carries the motor current, the input side sees the line current after filtering. Supply voltage is 380...480 V -10...10 %, and the frequency is locked to 50 Hz +/- 2 %. If the plant runs 60 Hz, this is the wrong filter. Operating temperature range is -25...45 °C without derating; above that, the thermal curve applies. The electrical connection uses, L2, L3, ', L2', L3' terminals (0.5...6 mm²) plus D and TS terminals for the DC bus and thermal sensor — the 1.5 mm² and 0.5...4 mm² capacities tell you the gauge for those auxiliary circuits. Insulation class N means it's double-insulated; no earth connection required on the filter body.

Frequently asked questions

What is the THDI of VW3A46102A?

The filter achieves a THDI of 10 % for the ATV610 variable speed drive at rated load, which reduces input current harmonics to a level suitable for shared line applications.

What standards does VW3A46102A comply with?

It complies with UL 61800-5-1 and IEC 61800-5-1, the safety standards for adjustable-speed drive systems.

How do I get current pricing and availability for VW3A46102A?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through our independent distribution network.

MPN
VW3A46102A