Overview
The VW3A46115: It dissipates 905 W of thermal loss at 98% efficiency, carries an IP20 enclosure, and meets IEC 61000-3-2, IEC 61000-3-4, IEC 61000-3-12, and G5/4 engineering recommendation for harmonic mitigation.
Lifecycle and sourcing
Schneider discontinued the VW3A46115 on 2024-08-15. Remaining units are sourced through surplus and broker channels.
How it compares
The VW3A46115 switches 252 A, while the functionally similar VW3A46114 switches 217 A. For high-power drives such as the ATV61H at 280 kW/450 hp, the VW3A46115 requires two filters per drive; the VW3A46114 uses one filter per drive for the ATV61H at 132 kW/200 hp. Choose the VW3A46115 when the drive rating demands the higher current capacity and dual-filter configuration.