Schneider Electric VW3A7E101 — AC Drive (VFD) 480V

Schneider VW3A7E101 Resistance Braking Unit, 420 kW at 400 V

MPNVW3A7E101
Obsolete

Schneider Electric VW3A7E101 resistance braking unit, 200 kW continuous power, 420 kW max braking power at 400 V, 785 V DC activation threshold, for Altivar 61/71 variable speed drives.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

VW3A7E101 — Identification
ParameterValue
Product typeResistance braking unit
VW3A7E101 — Environmental
ParameterValue
Operating ambient temperature-10...50 °C
Operating altitude2000 m
Relative humidityClass 3K3 without condensation
Storage / transport temperature-25...70 °C
Pollution degree2 conforming to EN 50178
Vibration resistance0.2 gn
VW3A7E101 — Protection & EMC
ParameterValue
Protection functionsIntegrated thermal protection by thermal probe
VW3A7E101 — Other specifications
ParameterValue
Load factor15 % at 320 kW (at constant power and at engage threshold) 50 % at 250 kW (at constant power and at engage threshold) 5 % at 420 kW
Thermal losses550 W
Continuous power200 kW
Operating positionVertical
Activation threshold785 V DC +/- 1 %
Volume of cooling air100 m3/h
Maximum DC bus voltage850 V
Maximum permanent braking power420 kW at 400 V (at constant power and at engage threshold)
Minimum resistor value to associate1.05 Ohm

Product details

Braking unit for Altivar 61/71 drives

The VW3A7E101 is a resistance braking unit sized for Altivar 61 and 71 variable speed drives up to 200 kW continuous motor power. It shunts excess regenerative energy from the DC bus into an external resistor bank, keeping the bus voltage from climbing past the drive's trip threshold during deceleration or overhauling loads. Maximum permanent braking power is 420 kW at 400 V, with a 785 V DC +/- 1 % activation threshold. The unit's load factor varies with the braking duty: 15 % at 320 kW, 50 % at 250 kW, and 5 % at 420 kW — these are the engage-threshold figures that govern how long the resistor can absorb power before cooling off.

Thermal and electrical limits

The unit dissipates 550 W of thermal losses internally, and requires 100 m³/h of cooling air volume to stay within the -10 to 50 °C operating ambient range. The maximum DC bus voltage it can handle is 850 V, and the minimum external resistor value to associate is 1.05 Ohm — pair a resistor below this floor and the braking chopper draws more current than the IGBTs can switch safely. Pollution degree 2 per EN 50178 (non-conductive pollution only, occasional condensation) and Class 3K3 relative humidity without condensation. Operating altitude is limited to 2000 m; above that, the air density drops and the cooling capacity falls off, so derate the braking power or add forced ventilation.

Obsolete — sourcing through independent channels

Schneider Electric lists the VW3A7E101 as obsolete. The braking unit is available through independent surplus and broker channels — quantities are lot-specific, and pricing is confirmed at RFQ against your BOM quantity. For a line-down situation, the unit's 785 V DC activation threshold and 1.05 Ohm minimum resistor value are the critical fit parameters. Any replacement braking unit — whether a new-old-stock VW3A7E101 or a functional equivalent from another supplier — must match these to avoid nuisance overvoltage trips or blown chopper transistors.

Frequently asked questions

How do I get current pricing and availability for VW3A7E101?

Pricing and availability are confirmed at quote time against your BOM quantity. Submit an RFQ through the storefront; the sourcing desk will check independent distribution channels and return a firm quote with lead time.