Siemens 3RT1065-2AM36 — Contactors

Siemens 3RT1065-2AM36 SIRIUS Power Contactor, S10, 200-220 V

MPN3RT1065-2AM36
Active

Siemens SIRIUS power contactor, size S10, 200-220 V AC/DC coil, screw fixing, spring-type terminals, 202 x 145 x 210 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT1065-2AM36 — Identification
ParameterValue
Contactor frame sizeS10
3RT1065-2AM36 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V230 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1065-2AM36 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.9
Rated value @ 50 Hz200 ... 220 V
3RT1065-2AM36 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1065-2AM36 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 500 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 400 A (690 V, 100 kA), aM: 315 A (690 V, 50 kA), BS88: 400 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1065-2AM36 — Connection & Mounting
ParameterValue
Main circuit connectionConnection bar
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0,25 ... 2,5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1065-2AM36 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1065-2AM36 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1065-2AM36 — Mechanical
ParameterValue
Width145 mm
Height210 mm
Depth202 mm
3RT1065-2AM36 — Specifications
ParameterValue
At AC40 ... 80 ms

Product details

SIRIUS S10 Power Contactor – 200-220 V Coil

The coil is rated 200-220 V AC/DC, with a pickup threshold of 0.8 x rated value and a dropout of 0.1 x rated value, making it suitable for applications where the control voltage is in that range. The contactor is fastened via screw fixing to a vertical mounting surface, rotatable ±90° and tiltable ±22.5° front/back, which gives flexibility in panel layout.

Ratings and Duty Cycles

The 3RT1065-2AM36 carries a rated operational current of 10 A at 24 V on the auxiliary contacts, and 2 A at 48 V and 60 V. The main contactor is rated for AC-1 duty at 800 switching cycles per hour, AC-3 at 500 cycles/h, AC-4 at 130 cycles/h, and AC-2 at 250 cycles/h. These ratings define the load type and switching frequency the contactor can handle without overheating or excessive wear.

The magnet coil termination uses spring-type terminals, accepting solid or stranded conductors of 2x (0.25-2.5 mm²). The main power circuit accepts stranded conductors of 70-240 mm². The auxiliary switch is present, with solid/stranded termination of 2x (0.25-2.5 mm²). The contactor has one mounting hole of 11 mm diameter. The enclosure dimensions are 202 mm depth, 145 mm width, and 210 mm height.

Frequently asked questions

How do I get current pricing and availability for 3RT1065-2AM36?

Pricing and availability are confirmed at quote time against an RFQ through independent distribution channels.

What is 3RT1065-2AM36's listed depth?

The depth is 202 mm.

What is 3RT1065-2AM36's listed solid conductor size?

The solid conductor size for the auxiliary circuit is 2x (0.25-2.5 mm²).

Will 3RT1065-2AM36 drop into a panel specified around 3RT1266-6AP36-0KA1 without rewiring?

The 3RT1065-2AM36 is a different size S10 contactor; the 3RT1266-6AP36-0KA1 is a different variant. Panel fit and wiring compatibility must be verified against the specific panel layout and terminal assignments.

MPN
3RT1065-2AM36