Skip to main content
Siemens 3RT2015-2AH01-ZX95 — Contactors

Siemens 3RT2015-2AH01-ZX95 SIRIUS Contactor, Size S00, 45 mm

MPN3RT2015-2AH01-ZX95
Active

Siemens SIRIUS 3RT2015-2AH01-ZX95 power contactor, Size S00, 45 mm width, spring-type coil terminals, screw and snap-on mounting on 35 mm DIN rail (DIN EN 60715), 73 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT2015-2AH01-ZX95 — Identification
ParameterValue
Contactor frame sizeS00
3RT2015-2AH01-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V6.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V0.75 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2015-2AH01-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz48 V
3RT2015-2AH01-ZX95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2015-2AH01-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2015-2AH01-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Side-by-side mountingYes
3RT2015-2AH01-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2015-2AH01-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2015-2AH01-ZX95 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth73 mm
3RT2015-2AH01-ZX95 — Specifications
ParameterValue
At AC7 ... 13 ms

Product details

Lifecycle and Sourcing Reality

The 3RT2015-2AH01-ZX95: As a current-production Siemens SIRIUS contactor, it is sourced through authorized distribution channels. Availability and current pricing are confirmed at RFQ against the BOM quantity.

Panel Fit and Mounting

Size S00 frame: 45 mm wide, 70 mm tall, 73 mm deep. The width is the critical dimension for DIN-rail density — at 45 mm it occupies one standard 45 mm module position on a 35 mm rail per DIN EN 60715. Mounting is dual-mode: screw-fixed or snap-on onto 35 mm standard mounting rail. The mounting position allows +/-180° rotation on a vertical surface and +/-22.5° tilt forward/backward, giving flexibility in tight enclosures. Clearance requirements: 10 mm upward, 10 mm forward, 10 mm downward, 6 mm at the side. These are the minimum air gaps for heat dissipation and arc flash clearance.

Wiring and Terminals

Main contact terminals accept solid or stranded wire: 0.5 to 4 mm² per conductor, or 2x (0.5 to 4 mm²) for paralleled feeds. The coil terminals are spring-type — push-in termination, no screw torque required. The auxiliary switch is factory-fitted (yes), so no separate add-on block is needed for basic signaling or interlocking.

Switching Performance and Duty Cycles

Rated for AC-1 (resistive) duty up to 1,000 operations per hour, AC-2 and AC-3 (motor starting) at 750 ops/h, and AC-4 (plugging/inching) at 250 ops/h. The AC-3e rating matches the AC-3 figure at 750 ops/h. Opening time (at AC) is 7 to 13 ms; arcing time is 10 to 15 ms. These timing windows are relevant for coordination with upstream protective devices and for assessing contact wear in high-cycle applications. Mechanical life of the contactor is typical 30,000,000 operations — a high-cycle rating suited for frequent switching in conveyor or pump control.

Environmental and Storage

Operating temperature range: -25 to +60 °C. Storage range: -55 to +80 °C. This covers most industrial enclosures and unheated warehouses.

Frequently asked questions

What wire sizes does the 3RT2015-2AH01-ZX95 accept?

Main contacts accept solid or stranded wire from 0.5 to 4 mm² per conductor, or 2x (0.5 to 4 mm²) for paralleled runs. Coil terminals use spring-type clamps for push-in wiring.

MPN
3RT2015-2AH01-ZX95