Skip to main content
Siemens 3RT2016-2BB41-ZW96 — Contactors

Siemens 3RT2016-2BB41-ZW96 SIRIUS Power Contactor, 24 VDC Co

MPN3RT2016-2BB41-ZW96

Siemens SIRIUS 3RT2016-2BB41-ZW96 power contactor, size S00, 24 VDC coil, spring-type terminals, 45 mm width, 73 mm depth, current lifecycle stage.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT2016-2BB41-ZW96 — Identification
ParameterValue
Contactor frame sizeS00
3RT2016-2BB41-ZW96 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V1 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2016-2BB41-ZW96 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT2016-2BB41-ZW96 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2016-2BB41-ZW96 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2016-2BB41-ZW96 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2016-2BB41-ZW96 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2016-2BB41-ZW96 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2016-2BB41-ZW96 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth73 mm

Product details

SIRIUS 3RT2016-2BB41-ZW96 — 24 VDC Coil Power Contactor, Size S00

It switches up to 10 A at 24 VDC and 3 A at 400 VAC, with a mechanical endurance typical of 30,000,000 operating cycles. The contactor mounts on a 35 mm DIN rail per DIN EN 60715, with a width of 45 mm, height of 70 mm, and depth of 73 mm — a compact footprint for panel integration.

The 10 A rating at 24 VDC is the DC-1 resistive load current — the contactor handles DC loads up to that level, but for inductive DC loads (DC-13) the rating drops significantly. At 48 VDC it is rated 2 A, and at 125 VDC only 0.9 A, so for a motor brake or solenoid valve on a 24 VDC bus, the 10 A figure is the one that governs fit. The 3 A at 400 VAC covers small three-phase motor loads in AC-3 duty (squirrel-cage motors starting and disconnecting under load), with a maximum switching frequency of 750 operations per hour in AC-3. The 1 hp rating at 230 VAC confirms its use on fractional-horsepower single-phase motors.

The contactor accepts solid or stranded wire from 0.5 to 4 mm², or 2x (0.5 to 4 mm²) for paralleled conductors. Spring-type terminals on the coil save wiring time — no screw torque to verify. The DC operating time (7 to 13 ms) and arcing time (10 to 15 ms) matter for coordination with upstream protection — the contactor clears faults within that window.

Frequently asked questions

What wire sizes does the 3RT2016-2BB41-ZW96 accept?

It accepts solid or stranded wire from 0.5 to 4 mm², or 2x (0.5 to 4 mm²) for paralleled conductors.

What are the mounting dimensions and clearances?

The contactor is 45 mm wide, 70 mm high, and 73 mm deep. Required clearances: 10 mm upward, 10 mm forward, 10 mm downward, and 6 mm at the side. It mounts on a 35 mm DIN rail per DIN EN 60715.

MPN
3RT2016-2BB41-ZW96