Siemens 3RT2024-2AP00-ZX95 — Contactors

Siemens 3RT2024-2AP00-ZX95 SIRIUS Power Contactor, S0 Size

MPN3RT2024-2AP00-ZX95
Active

Siemens SIRIUS power contactor, size S0, order code 3RT2024-2AP00-ZX95, spring-type terminals for the magnet coil, screw and snap-on 35 mm DIN rail mounting, 45 mm width, 102 mm height, 97 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RT2024-2AP00-ZX95 — Identification
ParameterValue
Contactor frame sizeS0
3RT2024-2AP00-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V12.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V2 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2024-2AP00-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz230 V
3RT2024-2AP00-ZX95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2024-2AP00-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 63A (690V,100kA), aM: 32A (690V,100kA), BS88: 63A (415V,80kA)
Short-circuit coordination type 2, fusegG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2024-2AP00-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid1 ... 10 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2024-2AP00-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2024-2AP00-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2024-2AP00-ZX95 — Mechanical
ParameterValue
Width45 mm
Height102 mm
Depth97 mm
3RT2024-2AP00-ZX95 — Specifications
ParameterValue
At AC4 ... 16 ms

Product details

It is the switching workhorse for motor loads, resistive heaters, and general inductive loads inside a control panel — the part you grab when a 3-phase motor needs a reliable make/break on a DIN rail. The coil termination uses spring-type terminals, so no screwdriver needed on the magnet coil circuit — just strip and push. That saves time during panel build or a field swap when you're working off a headlamp.

The contactor is rated for up to 1,000 switching cycles per hour in AC-1, AC-2, and AC-3 duty, dropping to 300 cycles per hour in AC-4. Wire termination on the main contacts accepts solid or stranded conductors from 1 mm² up to 10 mm², and you can double up 2x (0.5 to 2.5 mm²) on the same terminal. That covers most control-circuit wiring you'd run in a panel — no need for ferrule adapters or ring terminals.

Physical fit: panel and footprint

Dimensions are 45 mm wide, 102 mm tall, and 97 mm deep. The 97 mm depth leaves clearance for wiring ducts behind the rail. That 6 mm side gap is tighter than the vertical clearances — watch it when packing contactors side-by-side on the same rail to avoid arc-flash between phases.

Frequently asked questions

What are the key dimensions for panel layout?

The contactor measures 45 mm wide, 102 mm tall, and 97 mm deep. It requires 10 mm clearance above and below, 10 mm forward, and 6 mm at the sides.

What conductor sizes does it accept on the main contacts?

It accepts solid or stranded conductors from 1 to 10 mm² on the main contacts, and you can double up 2x (0.5 to 2.5 mm²) on the same terminal.

How does the 3RT2024-2AP00-ZX95 compare to the 3RT2024-2AG24?

Both are SIRIUS S0-frame power contactors, so they share the same physical footprint and DIN-rail mounting. The difference is in the coil voltage and terminal type — the -2AP00 variant uses spring-type terminals on the magnet coil, while the -2AG24 uses screw-type terminals. If your panel wiring is already set up for screw terminals, the -2AG24 drops in without changing termination tools. For new builds or if you prefer push-in wiring on the coil, the -2AP00 saves install time.

MPN
3RT2024-2AP00-ZX95