Siemens 3RV1011-1CA10-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV1011-1CA10-ZW97 SIRIUS Motor Protection Circuit B

MPN3RV1011-1CA10-ZW97
Active

Siemens SIRIUS, motor protection circuit breaker, 3RV1011-1CA10-ZW97, Trip Class 10, 100 kA interrupting capacity at 400 V, phase failure detection, screw and snap-on mounting onto 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV1011-1CA10-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV1011-1CA10-ZW97 — Electrical
ParameterValue
Rated operational current (Ie)2.5 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV1011-1CA10-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range1.8 ... 2.5 A
Instantaneous short-circuit trip current33 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)2 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV1011-1CA10-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV1011-1CA10-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV1011-1CA10-ZW97 — Mechanical
ParameterValue
Height90 mm
Width45 mm
Depth75 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV1011-1CA10-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV1011-1CA10-ZW97 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection circuit breaker — SIRIUS 3RV1011-1CA10-ZW97

Rated interrupting capacity reaches 100 kA at 240 V, 400 V, and 500 V, dropping to 2 kA at 690 V.

At 400 V, the datasheet specifies a gL/gG 35 A backup fuse; at 500 V and 690 V, gL/gG 25 A. At 240 V, no backup fuse is required. These are the coordination limits — exceed them and the interrupting capacity of the device alone is what clears the fault. The 2 kA rating at 690 V is a hard ceiling; if the available fault current at 690 V exceeds that, a current-limiting upstream device is mandatory.

The lifecycle stage for this order code is listed as current, meaning the manufacturer continues to produce it as a standard catalog item. No successor has been announced.

Mounting clearances and wiring

Clearance requirements per the datasheet: 20 mm upwards, 20 mm downwards, 9 mm at the side, 0 mm forwards, 0 mm backwards. These are the minimum free air spaces needed for heat dissipation and arc venting — not optional for maintaining the SCCR rating. Main circuit terminals accept 2×(0.5…1.5 mm²) or 2×(0.75…2.5 mm²) solid or stranded, with M3 screw-type terminals.

Environmental limits

The rated voltage range is 20…690 V. Maximum switching frequency under AC-3 or AC-3e duty is 15 operations per hour.

Frequently asked questions

How do I get current pricing and availability for 3RV1011-1CA10-ZW97?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

Will 3RV1011-1CA10-ZW97 drop into a panel specified around 3RV1011-0HA10 without rewiring?

Both are SIRIUS 3RV10 motor protection circuit breakers with the same 45 mm width and 90 mm height, and both mount on 35 mm DIN rail. The -1CA10-ZW97 has a different thermal setting range and interrupting capacity than the -0HA10 variant, so verify the motor FLA and available fault current against the nameplate before assuming a drop-in swap. Terminal wiring (M3 screw-type, 2×0.5…2.5 mm²) is identical.

What compliance documentation does Siemens provide for 3RV1011-1CA10-ZW97?

As a standard SIRIUS catalog item, the manufacturer provides a declaration of conformity to IEC/EN 60947-2 and 60947-4-1, along with RoHS and REACH compliance declarations. UL and CSA approvals are standard for the SIRIUS 3RV10 series. Specific cert numbers are available with the product documentation on request.