Skip to main content
Siemens 3RW5075-2TB15 — Soft Starters

Siemens 3RW5075-2TB15 Soft Starter, 160 A, 200-600 V, ATEX

MPN3RW5075-2TB15
Active

Siemens 3RW5075-2TB15 soft starter, 160 A minimum rated current, 200-600 V operating voltage, Class 10A/10E/20E trip, ATEX and IECEx approved, PROFIBUS and Modbus RTU/TCP enabled.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5075-2TB15 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5075-2TB15 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)200 kW
Rated motor power at 230 V (40 °C)110 kW
Rated operational current at 40 °C370 A
Rated operational current at 50 °C328 A
Rated operational current at 60 °C300 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)3 124 W
3RW5075-2TB15 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
3RW5075-2TB15 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5075-2TB15 — Mechanical
ParameterValue
Height230 mm
Width160 mm
Depth282 mm
Weight7.3 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5075-2TB15 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; derating as of 1000 m, see Manual
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5075-2TB15 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases2
Utilization category according to IEC 60947-4-2AC-53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
Ramp-Down Time Of Soft Starter0 ... 20 s
3RW5075-2TB15 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Active production, fieldbus-ready motor starting

The Siemens 3RW5075-2TB15 is a current-production soft starter rated for a minimum 160 A at 200-600 V, designed for three-phase induction motor starting with a preset Class 10A or selectable 10E/20E trip profile per IEC 60947-4-2. It carries onboard PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP interfaces, so it drops into a PLC-controlled line without a separate gateway module.

Trip class and motor protection

The 10E and 20E settings extend the ramp time for higher-inertia loads like centrifuges or crushers. The minimum load setting is 15 % of the smallest settable Ie, so it can start lightly loaded conveyors or pumps without nuisance tripping.

Compliance and approvals for hazardous areas

ATEX and IECEx certified, plus CE, UL, and CSA marks — this unit is panel-ready for Zone 2 / Zone 22 installations and North American 600 V class systems.

Mounting and panel integration

Screw-fixed mounting, 160 mm wide × 230 mm tall × 282 mm deep. Clearance requirements: 100 mm upward, 75 mm downward, 10 mm forward, 5 mm sideways — plan the enclosure depth and cable duct accordingly. Mounting position is vertical, rotatable ±90° or tiltable ±22.5° front-to-back, which gives flexibility in tight retrofit panels.

Frequently asked questions

Where can I buy 3RW5075-2TB15 and how do I get a price?

Submit an RFQ for current availability and pricing — confirmed at quote time.

What is 3RW5075-2TB15's listed ATEX certification?

ATEX certification is listed as Yes, along with IECEx, CE, UL, and CSA approvals. It is suitable for use in potentially explosive atmospheres per the applicable directives.

What is 3RW5075-2TB15's listed depth?

The depth is 282 mm. Combined with the 160 mm width and 230 mm height, plan for the enclosure depth plus the 10 mm forward clearance.

MPN