Siemens 3RW5215-3TC14 Soft Starter, 200-480 V, 11.5 A

MPN3RW5215-3TC14
Active

Siemens 3RW5215-3TC14 soft starter, hybrid switching device, 200-480 V, 11.5 A minimum, Trip Class 10A/10E/20E, 275 x 170 x 152 mm, screw fixing, PROFIBUS/Modbus/EtherNet/IP/PROFINET.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5215-3TC14 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5215-3TC14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)11 kW
Rated motor power at 230 V (40 °C)5.5 kW
Rated operational current at 40 °C43.3 A
Rated operational current at 50 °C39 A
Rated operational current at 60 °C33.9 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)318 W

Control & Connection

3RW5215-3TC14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typescrew-type terminals
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5215-3TC14 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5215-3TC14 — Mechanical
ParameterValue
Height275 mm
Width170 mm
Depth152 mm
Weight2.1 kg
Mounting position+/- 10° rotation possible and can be tilted forward or backward on vertical mounting surface
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5215-3TC14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5215-3TC14 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5215-3TC14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Panel fit and ventilation clearance

The 3RW5215-3TC14 measures 275 mm high by 170 mm wide by 152 mm deep. Screw fixing to the backplate is the standard mount; the mounting surface can tilt +/-10° from vertical. Ventilation gaps are mandatory: 100 mm above, 75 mm below, 10 mm forward, 5 mm to the side, and 0 mm backward. Without these clearances, the internal heatsink cannot shed the IGBT losses and the unit derates prematurely. Shock tolerance is 15 g / 11 ms.

Motor protection and trip class

Trip Class 10A is the default setting per IEC 60947-4-2, with selectable 10E and 20E profiles. Minimum settable current is 11.5 A, which sets the lower bound of the motor FLA it can protect. The minimum load is 15 % of the smallest settable Ie.

Fieldbus and control integration

The 3RW5215-3TC14 supports PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET. PROFIenergy is available with the PROFINET communication module. Firmware updates are supported in the field. An error logbook is accessible with special accessories. Auto-reset and remote reset by cycling the control supply voltage are standard.

Wiring terminals and power connections

Solid wire terminations accept two conductors per clamp: 1.0...2.5 mm² for control circuits, and 2.5...10 mm² for the main power path. Rated supply voltage is 200...480 V at 50/60 Hz.

Approvals and compliance documentation

The product category is hybrid switching devices.

Frequently asked questions

What is the trip class of the 3RW5215-3TC14?

The default trip class is CLASS 10A per IEC 60947-4-2, with selectable CLASS 10E and CLASS 20E profiles. Class 10A provides a 10-second maximum trip time at 7.2× Ie, suitable for standard motor starting duty.

What fieldbus protocols does the 3RW5215-3TC14 support?

It supports PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET. PROFIenergy is available when used with the PROFINET communication module.

What approvals does the 3RW5215-3TC14 carry?

The product is classified as a hybrid switching device.

What are the mandatory ventilation clearances for this soft starter?

Required clearances are: 100 mm above, 75 mm below, 10 mm forward, 5 mm to the side, and 0 mm backward. Without these, the unit will derate above 40 °C ambient.