Skip to main content
Siemens 3RW5216-1TC15 — Soft Starters

Siemens 3RW5216-1TC15 Soft Starter, 200-600 V, 14 A Min

MPN3RW5216-1TC15
Active

Siemens 3RW5216-1TC15 soft starter, 200…600 V, 14 A minimum, Trip Class 10A/10E/20E, PROFIBUS/Modbus/EtherNet/IP/PROFINET, 170 x 152 x 275 mm.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5216-1TC15 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5216-1TC15 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)15 kW
Rated motor power at 230 V (40 °C)7.5 kW
Rated operational current at 40 °C55.4 A
Rated operational current at 50 °C49 A
Rated operational current at 60 °C45 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)449 W

Control & Connection

3RW5216-1TC15 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typescrew-type terminals
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5216-1TC15 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5216-1TC15 — Mechanical
ParameterValue
Height275 mm
Width170 mm
Depth152 mm
Weight2.3 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5216-1TC15 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5216-1TC15 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5216-1TC15 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Trip class and motor protection curve

The 3RW5216-1TC15 is set up for Trip Class 10A by default, with selectable 10E and 20E per IEC 60947-4-2. Class 10A clears an overload in under 10 seconds at 7.2× FLC — tight enough to protect standard squirrel-cage motors during starting without nuisance tripping on high-inertia loads. Class 20E buys you extra time for loads like crushers or centrifugals that need a longer ramp. Minimum adjustable current is 14 A, which sets the floor for the motor FLC you can protect. Below that rating, the overload curve won't calibrate correctly.

Fieldbus and control integration

This soft starter carries onboard PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET — no separate communication module needed for most networks. The PROFINET interface also supports PROFIenergy for coordinated energy management during idle phases. Remote reset is handled by cycling the control supply voltage — useful for unattended restart after a fault clears.

Pump and torque control features

Pump Ramp Down is included — it extends the deceleration time to reduce water hammer in pump applications. Soft Torque mode provides a gentler acceleration profile for high-inertia loads like conveyors or centrifuges. Torque Control is not available on this unit — if you need closed-loop torque regulation during start, step up to the higher-feature variant.

Thermal derating and panel layout

In a sealed panel with other heat sources, budget for reduced continuous current above that threshold. Mounting is screw-fix to a vertical surface, rotatable ±90° and tiltable ±22.5° front-to-back. Clearance requirements: 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm at the sides, 0 mm backwards — tight enough for most enclosures. Dimensions are 170 mm wide, 152 mm deep, 275 mm high — fits a standard 600 mm deep cabinet with room for wiring ducts.

Wiring and termination

That covers both control wiring and main power cables up to about 8 AWG.

Approvals and compliance

Carries UL, CSA, and CE marking — accepted for panel builds in North America and the European Union without additional certification work.

Frequently asked questions

What compliance documentation does Siemens provide for 3RW5216-1TC15?

The unit carries UL, CSA, and CE approvals. The manufacturer typically provides a Declaration of Conformity covering the applicable IEC and EN standards; check the product documentation for specific RoHS/REACH declarations.

What is the minimum motor current this soft starter can protect?

Minimum adjustable current is 14 A. Motors with a full-load current below that cannot be properly protected by this unit.

Does 3RW5216-1TC15 support PROFINET?

Yes, PROFINET standard is supported onboard, along with PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP.

MPN
3RW5216-1TC15