Siemens 3RW5235-2AC05 — Soft Starters

Siemens 3RW5235-2AC05 SIRIUS Soft Starter, 68 A, 200-600 V

MPN3RW5235-2AC05
Active

Siemens SIRIUS 3RW5235-2AC05 soft starter, 68 A minimum, 200-600 V rated voltage, Class 10A/10E/20E trip class, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, PROFINET, screw fixing, 306 x 185 x 203 mm.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5235-2AC05 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5235-2AC05 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)75 kW
Rated motor power at 230 V (40 °C)37 kW
Rated operational current at 40 °C248 A
Rated operational current at 50 °C222 A
Rated operational current at 60 °C204 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)1 807 W

Control & Connection

3RW5235-2AC05 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5235-2AC05 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5235-2AC05 — Mechanical
ParameterValue
Height306 mm
Width185 mm
Depth203 mm
Weight6.6 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5235-2AC05 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5235-2AC05 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5235-2AC05 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Trip class and motor protection profile

The 3RW5235-2AC05 ships with a default trip class of CLASS 10A per IEC 60947-4-2, with selectable CLASS 10E and CLASS 20E profiles. For a pump or conveyor with a normal starting duty cycle, 10A is the baseline — it clears the start within 10 seconds at 600% locked-rotor current. If you're starting a high-inertia load like a centrifuge or a large fan, bump it to 20E so the soft starter doesn't nuisance-trip during the acceleration ramp. The minimum load setting is 15% relative to the smallest settable Ie — meaning if you're running a motor that draws well below the 68 A minimum, the soft starter may not regulate properly. Keep the motor FLA at or above 68 A to stay in the control band.

Fieldbus and control integration

This SIRIUS soft starter carries onboard PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET — all five protocols are available without an add-on module. If your plant runs a mixed-protocol environment, you can commission the same unit across different network segments by swapping the parameter set. The analog output is configurable as 4-20 mA (default) or 0-10 V via the High Feature HMI parameter set. This gives the PLC a live current signal for trending motor load without a separate transducer. PROFIenergy is supported when used with the PROFINET communication module — useful for shutting down non-critical loads during idle periods in automotive or machining lines.

Mounting, clearances, and thermal derating

The unit measures 306 mm high, 185 mm wide, and 203 mm deep — screw-fixing mount, not DIN rail. You need 100 mm clearance above, 75 mm below, 10 mm forward, and 5 mm on each side. Zero clearance required at the rear, so you can push it against the back panel. If the panel ambient hits 50 °C, expect the continuous current rating to drop — plan your wire sizing and thermal management accordingly. Mounting position is flexible: vertical surface with ±90° rotation, and ±22.5° tilt forward/back. That helps when the sub-panel is angled inside the enclosure.

Soft torque, pump ramp, and reset logic

Soft Torque is enabled — this reduces the initial current spike on high-friction loads like conveyors with stuck rollers. Pump Ramp Down gives a controlled deceleration profile for centrifugal pumps, preventing water hammer on the discharge line. Auto-reset is standard, and a remote reset is available by cycling the 24 V control supply. If the starter trips on a fault, the PLC can toggle the control voltage to clear the trip without a site visit. Shock resistance is rated at 15 g / 11 ms, with potential contact lifting above 12 g / 11 ms — fine for most industrial panels, but if the machine sees repetitive hammering (stamping presses, rock crushers), consider adding vibration dampers.

Compliance and documentation

The 3RW5235-2AC05 carries CE marking, UL approval, and CSA approval — covering the three major regulatory jurisdictions for industrial control panels. Firmware updates are supported, and an error logbook is available with special accessories — useful for tracking repeated fault conditions on a critical motor.

Sourcing and lifecycle status

For a panel originally specified around a different soft starter (e.g., 6ED1052-1MD08-0BA1 or 6ES7517-3FP00-0AB0), this unit will not drop in without rewiring — the footprint, mounting, and control wiring differ. A panel re-spin is required.

Frequently asked questions

What trip classes does the 3RW5235-2AC05 support?

The default trip class is CLASS 10A per IEC 60947-4-2, with selectable CLASS 10E and CLASS 20E profiles. Use 10A for normal starting duty, 10E for extended ramp times, and 20E for high-inertia loads.

What fieldbus protocols does the 3RW5235-2AC05 support?

It supports PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET — all five are integrated without an add-on module.

What are the clearance requirements for mounting the 3RW5235-2AC05?

You need 100 mm above, 75 mm below, 10 mm forward, and 5 mm on each side. Zero clearance at the rear.