Skip to main content
Siemens 3RW5235-2AC05

Siemens 3RW5235-2AC05 SIRIUS Soft Starter, 68 A, 200-600 V

MPN 3RW5235-2AC05
Active

Siemens SIRIUS 3RW5235-2AC05 soft starter, 68 A minimum, 200-600 V rated voltage, Class 10A/10E/20E trip class, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, PROFINET, screw fixing, 306 x 185 x 203 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5235-2AC05 specifications
ParameterValue
Mountingscrew fixing
Depth203 mm
Width185 mm
Height306 mm
Trip classCLASS 10 A (default) / 10E / 20E; acc. to IEC 60947-4-2
Service factor1

Product details

Trip class and motor protection profile

The 3RW5235-2AC05 ships with a default trip class of CLASS 10A per IEC 60947-4-2, with selectable CLASS 10E and CLASS 20E profiles. For a pump or conveyor with a normal starting duty cycle, 10A is the baseline — it clears the start within 10 seconds at 600% locked-rotor current. If you're starting a high-inertia load like a centrifuge or a large fan, bump it to 20E so the soft starter doesn't nuisance-trip during the acceleration ramp. The minimum load setting is 15% relative to the smallest settable Ie — meaning if you're running a motor that draws well below the 68 A minimum, the soft starter may not regulate properly. Keep the motor FLA at or above 68 A to stay in the control band.

Fieldbus and control integration

This SIRIUS soft starter carries onboard PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET — all five protocols are available without an add-on module. If your plant runs a mixed-protocol environment, you can commission the same unit across different network segments by swapping the parameter set. The analog output is configurable as 4-20 mA (default) or 0-10 V via the High Feature HMI parameter set. This gives the PLC a live current signal for trending motor load without a separate transducer. PROFIenergy is supported when used with the PROFINET communication module — useful for shutting down non-critical loads during idle periods in automotive or machining lines.

Mounting, clearances, and thermal derating

The unit measures 306 mm high, 185 mm wide, and 203 mm deep — screw-fixing mount, not DIN rail. You need 100 mm clearance above, 75 mm below, 10 mm forward, and 5 mm on each side. Zero clearance required at the rear, so you can push it against the back panel. If the panel ambient hits 50 °C, expect the continuous current rating to drop — plan your wire sizing and thermal management accordingly. Mounting position is flexible: vertical surface with ±90° rotation, and ±22.5° tilt forward/back. That helps when the sub-panel is angled inside the enclosure.

Soft torque, pump ramp, and reset logic

Soft Torque is enabled — this reduces the initial current spike on high-friction loads like conveyors with stuck rollers. Pump Ramp Down gives a controlled deceleration profile for centrifugal pumps, preventing water hammer on the discharge line. Auto-reset is standard, and a remote reset is available by cycling the 24 V control supply. If the starter trips on a fault, the PLC can toggle the control voltage to clear the trip without a site visit. Shock resistance is rated at 15 g / 11 ms, with potential contact lifting above 12 g / 11 ms — fine for most industrial panels, but if the machine sees repetitive hammering (stamping presses, rock crushers), consider adding vibration dampers.

Compliance and documentation

The 3RW5235-2AC05 carries CE marking, UL approval, and CSA approval — covering the three major regulatory jurisdictions for industrial control panels. Firmware updates are supported, and an error logbook is available with special accessories — useful for tracking repeated fault conditions on a critical motor.

Sourcing and lifecycle status

For a panel originally specified around a different soft starter (e.g., 6ED1052-1MD08-0BA1 or 6ES7517-3FP00-0AB0), this unit will not drop in without rewiring — the footprint, mounting, and control wiring differ. A panel re-spin is required.

MPN
3RW5235-2AC05